Egardia Bell box Скачать руководство пользователя страница 6

 

APPENDICES 

 Audible and light signals bell box 

 DIP switches bell box 

 
 
 
 

APPENDIX A: SOUND AND LIGHT SIGNALS BELL BOX 

The table below lists the various types of sound and light signals the bell box can emit. 
 
 

No delay time set 

 

 

 

 

 

A

A

l

l

a

a

r

r

m

m

 

 

s

s

y

y

s

s

t

t

e

e

m

m

 

 

  Sound signal 

  Light signal 

 Activate 

 ON 

  1 beep* 

 All LED indicators flash 1x 

 Activate 

 ON, partially 

1 beep* 

   All LED indicators flash 1x 

 Deactivate 

2 beeps*

 

   LED indicators flash in sequence (from 

left to right and back) 

 Deactivate 

 Alarm in memory 

Beep of 3 sec.

 

   LED indicators flash in sequence 2x 

(from left to right and back) 

 
 
 

Delay time set 

 

 

 

 

 

A

A

l

l

a

a

r

r

m

m

 

 

s

s

y

y

s

s

t

t

e

e

m

m

 

 

  Sound signal 

  Light signal 

Activate 

 ON 

Throughout delay time 
one beep per second 

All LED indicators flash 1x 

 Activate 

 ON, partially 

Throughout delay time 
one beep per second 

All LED indicators flash 1x 

Deactivate 

2 beeps 

LED indicators flash in sequence 
(from left to right and back) 

Deactivate 

 Alarm in memory 

Beep of 3 sec. 

LED indicators flash in sequence 2x 
(from left to right and back) 

Activate 

 Battery low 

5 beeps 

All LED indicators flash 3x 

Deactivate 

 Battery low 

5 beeps 

LED indicators flash in sequence 2x 
(from left to right and back) 

Activate 

 Tamper switch is not 

fully pressed to the wall 

5 beeps 

All LED indicators flash 3x 

Deactivate 

 Tamper switch is 

not fully pressed to the wall 

2 beeps* 

 

LED indicators flash in sequence 4x 
(from left to right and back) 

 
* When the siren is deactivated those sound signals cannot be heard. 
 

Содержание Bell box

Страница 1: ...installation guide Bell box ...

Страница 2: ...tinuous Continuous settings of DIP Fire alarm Beeps of 2 sec The 3 LED indicators flash switches number 3 and 4 Flood alarm Beeps of 2 sec The 3 LED indicators flash OVERVIEW BELL BOX 1 Battery switch To turn the bell box on or off 2 DIP switches To adjust the settings of the bell box 3 Tamper switch The alarm is triggered when this switch is activated 4 Mounting holes 4x To mount the bell box usi...

Страница 3: ...d a short beep sounds After 3 seconds all LED indicators of the bell box flash once The gateway beeps once to indicate the bell box is successfully registered To confirm LED 1 and LED 3 of the bell box will flash once and a short beep sounds The gateway beeps twice to indicate the bell box has already been successfully registered 6 Set DIP switch number 1 to OFF LED 2 of the bell box flashes once ...

Страница 4: ...switch number 6 back to OFF DIP switch number 7 configure whether the control function has to be activated or deactivated The control function is activated by default so that the bell box regularly transmits a control signal to the Egardia gateway STEP 3 MOUNT BELL BOX Place the bell box in a highly visible location on the exterior wall Before mounting use the key fob to test the desired mounting ...

Страница 5: ...gardia account you will see the message Battery low level under the tab Alarm history 3 You will receive a one time message by telephone SMS or email 4 The central indicator light Alarm of your gateway is lit yellow After the batteries have been replaced the gateway will return to normal status Replacing the batteries 1 Login to your Egardia account and click on the tab Alarm system 2 Click under ...

Страница 6: ... Sound signal Light signal Activate ON Throughout delay time one beep per second All LED indicators flash 1x Activate ON partially Throughout delay time one beep per second All LED indicators flash 1x Deactivate 2 beeps LED indicators flash in sequence from left to right and back Deactivate Alarm in memory Beep of 3 sec LED indicators flash in sequence 2x from left to right and back Activate Batte...

Страница 7: ...n OFF Default ON Installation mode DIP switch 2 Duration active LED indicators OFF During alarm ON Until alarm system is turned off DIP switch 3 DIP switch 4 Duration sound and light signals OFF OFF 3 min ON OFF 5 min OFF ON 10 min ON ON 1 second test DIP switch 5 Siren OFF Siren deactivated ON Siren activated DIP switch 6 Erase memory OFF Default ON Erase memory DIP switch 7 Control function OFF ...

Отзывы: