2

OPERATION AND MAINTENANCE MANUAL

Operating pressure

90 PSI

max. 6 bar

Air connection

R 1/2” female

R 1/2“

Motor output

1.61 HP

1,5 kW

Air consumption

21 cfm

1,5 m3/min

I/D of hose

0.51 inches

13 mm

Free speed

250 rpm

250 1/min

Speed under load

150 rpm

150 1/min

Percussion drilling under load

0-2500 blows/min

0-2500 Schläge/ min

Drilling range in concrete

0.4724 – 1.1968 inches dia.

Ø

12- 50 mm

Drilling capacity in concrete of medium 

hardness

0.7874 dia. =

7.078 cu. in = 

14.56 inches/ min

Ø

20 mm= 116 cm

3

/min 

= 370 mm/min

Optimum drilling performance in concrete

0.4724 -1.5748 inches dia.

Ø

20- 40 mm

Drilling in wood (with quick-release chuck)

0.3937 – 1.2598 inches dia.

Ø

10-32 mm

Motor oil capacity

3.05 cu.in.

50 cm

3

Weight (without hoses)

29.32 lbs

13.3 kg

Dimensions (L x H x W)

25.19x4.92x10.83 inches

640 x 125 x 275 mm

Tool holder

SDS Max

Sound level

90.4 dB (A)

Vibration measurement

9.2 m/s

2

Safety clutch for protection against overloading and accidents

Sealed Gears with permanent lubrication (maintenance free)

Adjustable side handle with depth gauge and water flushing.

Supplied kit: 1 carrying case, 1 dust guard, 1 oil ampul (50 cc)

Содержание Aqua Master 79908

Страница 1: ...HAMMER DRILLS OPERATING INSTRUCTIONS GUARANTEE 9 COD 79908...

Страница 2: ...cu in 14 56 inches min 20 mm 116 cm3 min 370 mm min Optimum drilling performance in concrete 0 4724 1 5748 inches dia 20 40 mm Drilling in wood with quick release chuck 0 3937 1 2598 inches dia 10 32...

Страница 3: ...standing on a ladder or leaning against a scaffold Secure the working place well Use clamps or a vice to fix the work piece This is safer than using hands and clears both hands for operating the machi...

Страница 4: ...and masonry The machine is intended to be used by professional operators Only authorized and trained personnel may use maintain and repair the machine The personnel has to be especially instructed on...

Страница 5: ...ion of shank end Occasionally clean shank ends and spray sparingly with lubricant sprayer Do not spray into the chuck Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 1 Drilling in explosive surroundings The drill m...

Страница 6: ...am of the machine if it is not possible to prevent the formation of rust and water condensation in the air distribution lines b The lubrication conditions and maintenance see Maintenance of pneumatic...

Страница 7: ...r removing the screw plug item 3 Theoil supply is decreased by tightening the screw and by loosening the screw more oil gets into the machine In most cases it is sufficient to tighten or loosen the sc...

Страница 8: ...OOTING Problem Cause Remedy a Machine does not start Air not connected Connect and open air line b Machine rotates too slowly Operating pressure too low Increase operating pressure on the machine to 6...