4. PRODUCT CHARACTERISTICS

- Incremental capacity measurement system

- Carbide measurement surface

- Built in wireless transmission(optional)

- Measuring force:5-10N

- Measuring power consumption: <60μA

- Working temperature: 0-40ºC           

- Storage and transportation: -20-60ºC

- Environmental humidity:<80%

- 3V CR2032 lithium battery, battery life>1 year.

Range of measurement

0-25mm/0-1” 

 

Accuracy of indication: 0.003mm/0.00015”

25-50mm/1-2”   

Accuracy of indication: 0.003mm/0.00015”

50-75mm/2-3”   

Accuracy of indication: 0.004mm/0.00015”

75-100mm/3-4”   

Accuracy of indication: 0.004mm/0.00015”

100-125mm/4-5”  

Accuracy of indication: 0.005mm/0.0002”

125-150mm/5-6”  

Accuracy of indication: 0.005mm/0.0002”

Caution

Although you own the high-quality product, like any other electronic product, appropriate 

attention is necessary.

1. Please clean the measuring surface before using the micrometer to reduce the measurement 

error.

2. To avoid product contacted with liquid, exposure in sunshine, do not wash the product, do not 

disassemble or collide the product..

3. Do not place the micrometer in an overheated or supercooled environment or in a strong 

magnetic or high-pressure environment.

4. About the battery: forbid to charge or burn, the old battery must be disposed according to the 

local laws and regulations

5. In order to ensure the good condition of measuring tool for long time, clean the oil 

contamination and liquid on the measuring tool with the soft cloth after using.

6. If you do not use for a long time, please take out the battery.

6. FAILURE REMOVAL

Problem

Cause

Solution

Measuring data incorrect

1. Dirty measuring faces

2. Zero is incorrect

1. Clean measuring faces

2. Inspect and reset zero

No display on LCD

1. Battery position is incorrect

2. Battery is dead

1. Reset battery

2. Replace with new battery

1. Flickering display

2. Display sporadic

3. Display remains dead

1. Weak battery

2. Weak battery

3. Battery position is incorrect

1. Replace battery

2. Replace battery

3. Reset battery

1. Display is blurry

2. Output data is incorrect

Weak battery

Replace with battery

Содержание 66266

Страница 1: ...PARA EXTERIORES OUTER DIGITAL MICROMETER MICROMÈTRE DIGITAL EXTÉRIEUR COD 66266 BLUETOOTH ESPAÑOL 2 ENGLISH 6 FRANÇAIS 10 GARANTIA GUARANTEE GARANTIE 15 MANUAL DE INSTRUCCIONES OPERATING INSTRUCTIONS MANUEL D INSTRUCTIONS ...

Страница 2: ...fino con fuerza constante para garantizar la precisión de la medición 6 Pantalla LCD muestra el valor de medición 7 Conector de salida salida de datos SPC el formulario bluetooth se puede usar para la fuente de alimentación 8 Llave de bloqueo bloquee la posición en el sentido de las agujas del reloj y suelte el bloqueo en el sentido contrario a las agujas del reloj 9 Varilla medidora 2 PASOS DE US...

Страница 3: ...o Después de conectar aparecerá en la pantalla todo el tiempo Si no se puede conectar en 5 minutos desaparecerá la herramienta de medición saldrá del modo de búsqueda automáticamente Si continúa la conexión repita las acciones anteriores 2 Enviar datos después de conectarse presione brevemente el botón DATA los datos se pueden enviar al dispositivo receptor ordenador teléfono la pantalla parpadear...

Страница 4: ...n 0 005 mm 0 0002 Precaución Aunque usted posee el producto de alta calidad como cualquier otro producto electrónico es necesaria la atención adecuada 1 Limpia la superficie de medición antes de usar el micrómetro para reducir el error de medición 2 Para evitar que el producto entre en contacto con líquidos la exposición a la luz solar no lave el producto no lo desmonte ni lo golpee 3 No coloque e...

Страница 5: ...l funcionamiento del aparato en caso de un uso incorrecto o se haya utilizado para trabajos para los que no está diseñado Según la directiva sobre residuos eléctricos de aparatos eléctricos y electrónicos RAEE éstos deberán recogerse y tratarse por separado Si en el futuro tiene que deshacerse de este producto no se deshaga de él junto con la basura doméstica Póngase en contacto con su distribuido...

Страница 6: ...isplay measurement value 7 Output connector SPC data output the bluetooth form can be used for power supply 8 Locking wrench lock the position clockwise and release the lock anticlockwise 9 Measuring rod 2 USE STEPS Before use please make sure that the battery is installed 1 Loosen the lock wrench of the micrometer counter clockwise to release the lock 2 Turn on to check if the micrometer display ...

Страница 7: ...ill disappear the measuring tool will exit the searched mode automatically If continuing connection please repeat the above actions 2 Send data After connecting short press DATA button data can be sent to the receiving device computer phone the screen will winkle at the same time to remind that data has been sent When the measuring tool and receiving device match and connect please try to keep the...

Страница 8: ...th liquid exposure in sunshine do not wash the product do not disassemble or collide the product 3 Do not place the micrometer in an overheated or supercooled environment or in a strong magnetic or high pressure environment 4 About the battery forbid to charge or burn the old battery must be disposed according to the local laws and regulations 5 In order to ensure the good condition of measuring t...

Страница 9: ...se ones must be collected and arranged separately If you have to throw them out please do not use the usual rubbish Please contact your distributor for free recycling GUARANTEE The maker guarantees to the device owner 12 months against any manufacture defect This guarantee do not cover the parts wich are consumables Note to apply the guarantee its necesary to send the GUARANTEE CERTIFICATE duly fi...

Страница 10: ...ante pour garantir la précision de la mesure 6 Écran LCD affiche la valeur de mesure 7 Connecteur de sortie sortie de données SPC la forme Bluetooth peut être utilisée pour l alimentation 8 Clé de verrouillage verrouillez la position dans le sens des aiguilles d une montre et relâchez le verrou dans le sens inverse des aiguilles d une montre 9 Jauge 2 ÉTAPES D UTILISATION Avant utilisation assurez...

Страница 11: ...tra à l écran tout le temps Si vous ne pouvez pas vous connecter en 5 minutes disparaîtra l outil de mesure quittera automatiquement le mode de recherche Si la connexion continue répétez les actions ci dessus 2 Envoyer des données après la connexion appuyez brièvement sur le bouton DATA les données peuvent être envoyées à l appareil de réception ordinateur téléphone l écran clignote en même temps ...

Страница 12: ... haute qualité comme tout autre produit électronique un entretien approprié est nécessaire 1 Veuillez nettoyer la surface de mesure avant d utiliser le micromètre pour réduire l erreur de mesure 2 Pour éviter tout contact du produit avec un liquide ou une exposition au soleil veuillez ne pas laver le produit ne pas le démonter ou le frapper 3 Ne placez pas le micromètre dans un environnement surch...

Страница 13: ...acer par la batterie NOTES IMPORTANT Le fabricant ne se responsabilise pas des détériorations ou du mauvais fonctionnement de la machine dans le cas d une mauvaise utilisation ou suite à des usages pour lesquels elle n est pas conçue Selon la directive des déchets d appareils électriques et électroniques DEEE ces derniers devront se ramasser et suivre un traitement séparé Si dans l avenir vous dev...

Страница 14: ...14 ...

Страница 15: ... A PARTIR DE LA DATE D ACHAT EJEMPLAR PARA EGA MASTER COPY FOR EGA MASTER EXEMPLAIRE POUR EGA MASTER ARTICULO ITEM ARTICLE Nº DE SERIE SERIE Nº Nº SERIE DISTRIBUIDOR DISTRIBUTOR DISTRIBUTEUR PAIS COUNTRY PAYS TEL FECHA DE VENTA SALE DATE DATE VENTE NOMBRE DEL COMPRADOR BUYER NAME NOM DE L ACHETEUR TEL COMPRADOR BUYER TEL TEL DE L ACHETEUR CERTIFICADO DE GARANTIA GUARANTEE CERTIFICATE CERTIFICAT DE...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Отзывы: