background image

15

maintenance center of our company for repair by professional service man, do not repair it without 

authorization.

- Especially in the process of using, keep the sensitive mirror of luxometer away from scratch or 

dirt to avoid damaging the mirror or influencing the measuring precision.

- Remove the battery if it won’t be used for a long time.

- Store the luxometer in a place free of moist, high temperature and strong magnetic field.

NOTES

IMPORTANT! 

The maker will not take responsibility for damage or malfunction as a result of the device being 

incorrectly used or, applied for a purpose for whith it was not intended.

 According to Waste Electrical and Electronic Equipment directive (WEEE), these ones must 

be collected and arranged separately. If you have to throw them out, please, do not use the usual 

rubbish. Please, contact your distributor for free recycling.

GUARANTEE

The maker guarantees to the device owner 12 months against any manufacture defect.
This guarantee do not cover the parts wich are consumables.

Note: to apply the guarantee its necesary to send the “GUARANTEE CERTIFICATE” duly filled 

within one week after purchased the machine to the maker.

Содержание 51266 Series

Страница 1: ...MANUAL DE INSTRUCCIONES OPERATING INSTRUCTIONS LUX METRO LUXOMETER ESPA OL 2 ENGLISH 9 GARANTIA GUARANTEE 17 COD 51266...

Страница 2: ...ca la iluminancia recibida en la superficie directa desde la fuente de luz de 1 candela con 1 metro de distancia de la superficie iluminada abreviado como Lux El lux metro puede hacer pruebas de ilumi...

Страница 3: ...gas vapor y polvo explosivo No desmonte la cubierta del lux metro sin autorizaci n para evitar da os en el mismo Ponga especial atenci n al sensor de captaci n de luz y mant ngalo limpio y sin rayarlo...

Страница 4: ...dad de la lectura entre Lux y FC 3 Bot n de selecci n de valor m ximo o m nimo pulse la tecla para cambiar entre medici n normal m ximo y m nimo El orden de selecci n es medici n normal MAX MIN Cuando...

Страница 5: ...ento autom tico que aparece en la pantalla principal Pulse el bot n MENU para cambiar de funci n o pulse HOLD para salir de la funci n de ajustes guardando as los cambios realizados Pulse y mantenga e...

Страница 6: ...ngulo y entorno Aseg rese de que no este rayado ni que haya suciedad en el sensor de captaci n de luz de lux metro o los datos de medici n no ser n exactos Cuando la iluminaci n exceda el rango de med...

Страница 7: ...alaci n y sustituci n de la bater a Cuando el indicador de la bater a aparezca en la pantalla del lux metro reemplace la bater a inmediatamente Sustituya la bater a de la siguiente manera Apague el lu...

Страница 8: ...deben ser recogidos y dispuestos por separado Si usted tiene que tirar por favor no use la basura habitual Por favor p ngase en contacto con su distribuidor para el reciclaje de forma gratuita GARANT...

Страница 9: ...ed as Lux Cod 51266 series can test illuminance within 0 20 000Lux II UNPACKING INSPECTION Unpack and check if there is any damage or loss contact with the nearest local sales service agency Mainframe...

Страница 10: ...losive gas steam and dust Do not dismantle the shell of luxometer without authorization to avoid luxometer damage Do not charge the battery to avoid battery explosion and personal injury Please pay at...

Страница 11: ...ing between Lux and FC 3 Maximum value and minimum value selection key under measuring state press the key to switch between normal measurement MAX and MIN in order of normal measurement MAX MIN When...

Страница 12: ...splayed on the main display press RANGE or MAX MIN key to adjust the auto memory interval displayed on the main display press MENU key to enter next function setting or press HOLD to exit function set...

Страница 13: ...ting source and illuminometer positions or different of them or the environment is different then the measured data will be different cause the intensity of light varies with change of distance positi...

Страница 14: ...20FC 0 01FC 200FC 0 1FC 2000FC 1FC VII MAINTENANCE Warning During replacing battery or measuring keep the sensitive mirror from scratch or dirt to avoid damaging the mirror or influencing the measuri...

Страница 15: ...ibility for damage or malfunction as a result of the device being incorrectly used or applied for a purpose for whith it was not intended According to Waste Electrical and Electronic Equipment directi...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: