8

Drop Test: 1 meter pass
Battery: 4 x 1.5V batteries (AA)
Battery Life: Typical 20 hours continuous
Dimension: 273 x 69 x 39mm
Weight: around 386 g (including batteries)

B. Environmental Requirements

For indoor use only.
Altitude: 2000m
Temperature and humidity:

Operating:

0ºC ~30ºC (≤80%R.H)
30ºC ~40ºC (≤75%R.H)
40ºC ~50ºC (≤45%R.H)

Storage:

-20ºC ~ +60ºC (≤80%R.H)
Safety/ Compliances:

EN61326:1997+A1:1998+A2:2001+A3:2003,
EN61672-1: 2002 Class 2 and IEC60641:1979 Type 2,
ANSI S1.4:1983 Type 2

Certification: 

ACCURACY SPECIFICATIONS

Accuracy:±(a% r b digits).guarantee for 1 year.

Operating temperature: 23ºC±5ºC .

Relative humidity:≤80%.
Temperature coefficient: 0.1 x (specified accuracy) / 1ºC

DECIBEL dB

Function

Range

Resolution

Accuracy

Remarks

A-Weighting and 

C-Weighting

30~80dB

0.1dB

±1.5dB

Frequency 

Response

31.5~8kHz

50~100dB
60~110dB
80~130dB

Sampling Rate

FAST

Sampling Time: 

125 microsecond

SLOW

Sampling Time: 1 

second

Analogue Bar 

Graph

30~130dB

1dB

1 dB per scale, 

Sampling time: 

200 times per  

second

Содержание 51263

Страница 1: ...OPERATING INSTRUCTIONS SOUND METER GUARANTEE 13 COD 51263...

Страница 2: ...r inspect the case and accessories Do not use the Meter if it is damaged LCD cannot display the case or part of the case is removed or you consider the Meter does not work properly Look for cracks or...

Страница 3: ...e battery as soon as leaking appears A leaking battery will damage the Meter INTERNATIONAL ELECTRICAL SYMBOLS Conforms to Standards of European Union THE METER STRUCTURE see figure 1 figure 1 A Meter...

Страница 4: ...d value display 8 Range display 9 Over range 10 Slow response 11 Fast response 12 Low battery display 13 Data Hold is on 14 Auto power off enabled 15 Under range 16 Analogue bar graph display 17 Symbo...

Страница 5: ...to plug in the terminal It can use 4pcs of 1 5V batteries or power adaptor to power up the Meter MEASUREMENT OPERATION AND FUNCTIONAL BUTTONS Below table indicated for information about the functiona...

Страница 6: ...noises that occur very quickly Select the LOW response to monitor a sound source that has a consistent noise level or to aver age quickly changing levels Select LOW response for most application Press...

Страница 7: ...n using 94dB 1kHz standard sound source 5 Adjust the Meter s CAL potentiometer located on the side panel until the LCD displays 94 0dB figure 4 SPECIFICATIONS A General Specifications Display 3 1 2 di...

Страница 8: ...3 2003 EN61672 1 2002 Class 2 and IEC60641 1979 Type 2 ANSI S1 4 1983 Type 2 Certification ACCURACY SPECIFICATIONS Accuracy a reading b digits guarantee for 1 year Operating temperature 23 C 5 C Relat...

Страница 9: ...of fast or slow sampling rate and turn on and off of display backlight Press to store data MAX MIN Auto ranging Selection of maximum and minimum value Selection of auto power on and off MAINTENANCE T...

Страница 10: ...r appears To replace battery 1 Press the Meter power off 2 Remove the screw from the battery compartment and then take out the battery door from the battery compart ment 3 Remove the battery from the...

Страница 11: ...wner 12 months against any manufacture defect This guarantee do not cover the parts wich are consumables Note to apply the guarantee its necesary to send the GUARANTEE CERTIFICATE duly filled within o...

Страница 12: ...12...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Отзывы: