background image

EFX 

(Entertainment FX)

 

OPERATION of Control Panel

 

1.

 

All operations on the Haze Machine are accessed from the Control panel. There are six con-
trol buttons located below the LCD display, these will navigate through the various functions. 
(refer to the diagram).

 

2.

 

To navigate the LCD controls use the 

FUNCTION

 button to scroll through the various menu 

options. Then scroll through the menu options selectable values, use the 

UP/DOWN

 buttons. 

Press the 

FUNCTION

 to save any changes made and return to navigation the menu.

 

3.

 

Once a DMX signal is received, manual activation is deactivated and the buttons 

TIMER, 

START/STOP 

and 

MANUAL 

ar e locked.

 

Interval and Duration Settings

 

Control Panel Menu Structure

 

INTERVAL SET

 

DURATION SET

 

DMX512 Add

 

FLUID SET

 

0s

-

200s (seconds)

 

Pause time between timed output

 

0s

-

200s (seconds)

 

Duration time of timed operation

 

1

-

512

 

Set the starting DMX address

 

On

 

Off

 

Low fluid shutdown on

 

Low fluid shutdown off

 

VOLUME SET

 

1% 

-

 100%

 

Set the volume output

 

FAN SPEED SET

 

1% 

-

 100%

 

Set the fan speed

 

Interval settings control the period of time in between timed haze outlets (seconds), while duration set-
tings are used to control the actual period of time the machine is hazing whilst using the timer mode.

 

1.

 

Press 

FUNCTION

 repeatedly until 

INTERVAL SET 

or 

DURATION SET 

shows on the 

display.

 

2.

 

Use 

UP/DOWN 

to select the number of seconds (0

-

200)

 

3.

 

Press the 

TIMER

 button to try your newly configured timer settings.

 

Timer Mode

 

1.

 

Press 

TIMER

 and the display will show a countdown of the interval time.

 

2.

 

When the interval countdown reaches zero (0), the unit will start the duration countdown, 
producing haze for the amount of time set in 

DURATION SET

.

 

Отзывы: