C556 Self Powered Elliptical Fitness Crosstrainer
Page 50
Procedure 7.17 - Replacing an Upper Pivot Arm
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
1.
Remove the bolt that fastens the upper pivot arm to the lower pivot arm. See Diagram 7.12.
2.
Remove the cap from the upper end of the upper pivot arm. Remove the bearing shaft from
the upper end of the upper pivot arm. The bearing shaft will be very tight, a long handled
socket wrench with a 7/16” hex key will be necessary for removal. See Diagram 7.13.
Diagram 7.13 - Upper Pivot Arm
3.
Remove the upper pivot arm from the unit.
4.
Set the upper end of the upper pivot arm in it’s mounting position and carefully thread the
bearing shaft into the frame. Care must be taken to avoid cross-threading the bearing shaft.
5.
Replace the lower mounting bolt, removed in step 2, and torque it to 200 inch pounds.
6.
Torque the bearing shaft to 150 foot pounds (1800 inch pounds).
7.
Insert the cap into the upper end of the upper pivot arm.
Bearing
Shaft
Cap