Operation
Page 78
Permitted value
ranges for battery
parameters
Factory
defaults
Min. Max. User-
defined
value:
Switch-on voltage
12.3 V
11 V
13 V
Switch-off voltage
14.2 V
13.5 V
14.7 V
Switch-off current
2 A (4 A EFOY
Comfort 210)
1 A
10 A
Switch-on delay
60 s
2 s
300 s
Absorption time
180 min
0 min
300 min
Battery protection
menu
ok
!
You can select the following menu options
in the "Battery protection" menu:
-
Switch-on voltage
-
Enable
-
Factory defaults
This option allows you to undo all battery
protection settings. Press
[ok]
to confirm
or
[
2
]
to cancel.
•
Press
[ok]
to access each menu.
CAUTION!
Incorrectly set operating parameters may damage the device. This may
nullify your warranty.
Please only use the precise values permitted for the battery parameter
and battery protection settings.
CAUTION!
If you stop protective charging manually, battery protection is disabled
until the next time the fuel cell is started. Deep discharge may damage
your battery.