The EFFI-Flex-LG requires 24V DC input power. Note the trigger pin needs to be connected to a PNP trigger signal.
Power Supply
Power supply / Electrical Input
24V DC +/-10%
Connector
(depending on the power consumption)
1x M12 - 5 pins or 1x M12 Power (T-coded) - 4 pins
If M12 Power - indicated in the product reference EFFI-FLEX-LG-XXXX-ZZZ-WW-PP-
1M12P
Power consumption
Average
Approx. 20W for each 200mm.
Peak (Max)
6A max for XXXX<1000mm - 12A max for XXXX
≥
1000mm
Inrush
6A max - 50ms max for XXXX<1000mm - 12A - 50ms max for XXXX
≥
1000mm
Max consumption strobe signal (PNP)
2mA
M12 - 5 pins
male connector
1 +24 V
Brown cable
PNP TRIGGER 4
(Light ON if VPNP> 4VDC)
Black cable
GND
3
Blue cable
M12 Power (T-coded) - 4 pins
male connector
1 +24 V
Brown cable
PNP TRIGGER 4
(Light ON if VPNP> 4VDC)
Black cable
GND
3
Blue cable
MegaStrobe feature
MegaStrobe
Strobing time (internal protection)
400µs max
Frequency (internal protection)
150Hz max
Rising time
<1µs
Falling time
<2µs
Initialization phase
When EFFI-Flex-LG is supplied, the product first enters in a few seconds initialization phase. This initialization is a sequence of very
short strobes of increasing intensity. Please wait until the end of this initialization to use the product (max 5 seconds).
CHS/CHO CONFIGURATIONS (DAISY-CHAIN OPTIONS)
You can chain several EFFI-Flex-LG-CHS by connecting the output connector directly to the next EFFI-Flex-LG bars. The EFFI-Flex-LG-
CHS / EFFI-Flex-LG-CHO requires the use of a standard 5 pin M12 cable (or a 4 pins M12 Power cable depending on the product’s
connector) to effectively chain the lights.
The number of bars possible to chain depends on the product software and the cables’ length.
With the standard software and 1 meter cables, the number of chainable products is:
The consumption values are maximum values, the exact power consumption of the product is always indicated on the product label.