background image

www.effilux.com

3/6

USER MANUAL EN EFFI-FLEX-LG-CGX V1.0.2022

How to connect the EFFI-Flex-LG?

The EFFI-Flex-LG requires 24V DC input power. Note the trigger pin needs to be connected to a PNP trigger signal.

Power Supply

Power supply / Electrical Input

24V DC +/-10%

Connector 

(depending on the power consumption)

1x M12 - 5 pins or 1x M12 Power (T-coded) - 4 pins

If M12 Power - indicated in the product reference EFFI-FLEX-LG-XXXX-ZZZ-WW-PP-

1M12P

Power consumption

Average

Approx. 20W for each 200mm. 

Peak (Max)

6A max for XXXX<1000mm - 12A max for XXXX

1000mm

Inrush

6A max - 50ms max for XXXX<1000mm - 12A - 50ms max for XXXX

1000mm

Max consumption strobe signal (PNP)

2mA

M12 - 5 pins

male connector

1 +24 V

Brown cable

PNP TRIGGER 4

(Light ON if VPNP> 4VDC)

Black cable

GND 

3

Blue cable

M12 Power (T-coded) - 4 pins

male connector

1 +24 V

Brown cable

PNP TRIGGER 4

(Light ON if VPNP> 4VDC)

Black cable

GND 

3

Blue cable

MegaStrobe feature

MegaStrobe

Strobing time (internal protection)

400µs max

Frequency (internal protection)

150Hz max

Rising time

<1µs

Falling time

<2µs

Initialization phase

When EFFI-Flex-LG is supplied, the product first enters in a few seconds initialization phase. This initialization is a sequence of very 

short strobes of increasing intensity. Please wait until the end of this initialization to use the product (max 5 seconds).

CHS/CHO CONFIGURATIONS (DAISY-CHAIN OPTIONS)

You can chain several EFFI-Flex-LG-CHS by connecting the output connector directly to the next EFFI-Flex-LG bars. The EFFI-Flex-LG-

CHS / EFFI-Flex-LG-CHO requires the use of a standard 5 pin M12 cable (or a 4 pins M12 Power cable depending on the product’s 

connector) to effectively chain the lights. 
The number of bars possible to chain depends on the product software and the cables’ length.
With the standard software and 1 meter cables, the number of chainable products is:

The consumption values are maximum values, the exact power consumption of the product is always indicated on the product label.

ELECTRICAL INSTALLATION - STD CONNECTOR CONFIGURATION

Отзывы: