UPS OUTPUT: BY PASS
Automatic static by-pass
Electronic thyristor switch
Protection
Fuses
Bypass
Vac
Three-phase + Neutral
Nominal Voltage (selectable)
Range
Vac
%
380
– 400 – 415
±10
Nominal Frequency (selectable)
Range
Hz
%
50-60
± (1 5) adjustable
Transfer mode
Without break
Transfer inverter
automatic bypass
In case of :
- Short circuit
- Battery end of discharge
- Inverter test
- Inverter not operating
Retransfer automatic bypass
inverter
- Automatic
- Block on bypass after 6 transfers within 2
minutes, reset by front panel
Overload Capability
%
150 continuously
1000 for 1 cycle
Manual By-Pass
Standard:
- Electronically controlled
- No break
Back feed protection
Standard