background image

UPS 

Uninterruptible Power Supply 

ME 400/500/600/650/800 

 

 

 

Instruction Manual 

Item number:  

ACX11MES40000000  USB 

 

ACX11MES50000000  USB 

 

ACX11MES60000000  USB 

 

ACX11MES65000000  USB 

 

ACX11MES80000000  USB

 

Juni 2008

 

Содержание ME 400

Страница 1: ...PS Uninterruptible Power Supply ME 400 500 600 650 800 Instruction Manual Item number ACX11MES40000000 USB ACX11MES50000000 USB ACX11MES60000000 USB ACX11MES65000000 USB ACX11MES80000000 USB Juni 2008...

Страница 2: ...rning indicator and operating elements 13 6 1 2 Operator control elements of the UPS 13 6 1 3 Display elements of the UPS 13 6 2 Equipment elements on the rear panel 14 6 3 Audible alarm signals of th...

Страница 3: ...nance and servicing 26 13 1 Measuring the bridging time support time 26 13 2 Service log 27 13 3 Service hotline 28 13 4 Maintenance and service contracts 28 14 Technical Data 29 14 1 Equipment specif...

Страница 4: ...al information and tips Recycling symbol Denotes components that are governed by the electronic scrap ordinance Denotes components or parts that must be disposed of in a specific manner Never throw th...

Страница 5: ...ral disasters misuse vandalism inappropriate use maintenance errors or incorrect repairs by third parties o Modifications unauthorised tampering incorrect operation another device or accessory incorre...

Страница 6: ...s for losses or damage made by third parties against you o Loss of or damage to your records or data or the cost of their recovery o Financial consequential damage including loss of earnings or saving...

Страница 7: ...transported to its place of intended use in the original packaging The same applies for removals or returns The equipment must not be transported or stored upside down Position the equipment securely...

Страница 8: ...load must always be installed directly in front of it and never centrally in front of the UPS Do not operate any household appliances and power tools e g fan heaters vacuum cleaners drills hairdryers...

Страница 9: ...oxic Defective batteries must be disposed of in an environmentally friendly manner Never throw batteries into the regular refuse The local waste disposal regulations must be observed 3 7 Maintenance s...

Страница 10: ...lity for errors in this description or their consequences The purpose of UPS Uninterruptible Power Supply equipment is to protect sensitive electrical devices such as computers workstations electronic...

Страница 11: ...inues without interruption to deliver a modified sine wave voltage supply to the UPS output In support mode the energy is drawn from the battery pack Fig 1 Block diagram ME series The block circuit di...

Страница 12: ...arious elements of the equipment and will be provided with instructions on its operation as well as all information on equipment connections 6 1 Display and operator control elements on the front pane...

Страница 13: ...of the specified maximum load Providing the mains power supply remains on via the fuse positioned at the rear of the UPS the charging unit also continues to operate even after the UPS has been switche...

Страница 14: ...ections on the rear panel with the exception of the communication interface are on the mains power potential when connected Even when disconnected dangerously high voltages may be present at the plug...

Страница 15: ...ilure protection d UPS output 10A IEC socket IEC320 Output without power failure protection The output only provides protection against excessive voltage from the mains power supply The protective ear...

Страница 16: ...notification sounds in the following sequence A beep beep long pause 3 s beep beep repeating Support mode and low battery capacity The audible warning notification sounds in the following sequence B b...

Страница 17: ...must be brought into operation for approx 8 hours to prevent deep discharge of the batteries 7 2 Unpacking the equipment Remove the shipping cartons and packaging material Always store the equipment...

Страница 18: ...port must be sufficient o Observe the specified installation position The specified installation position is upright vertical only o Make sure that ventilation of the equipment is possible at all time...

Страница 19: ...is complied with up to the last consumer load o the earthing of the consumer loads is ensured o or that the consumer loads are separately protected against overcurrents and leakage currents and are al...

Страница 20: ...essages in this operating mode Startup mode If the mains power is available the startup procedure is initiated when the ON OFF switch on the front of the equipment is pressed then on line mode is auto...

Страница 21: ...uence A Overload mode If the UPS output is overloaded the UPS switches off after a short time interval approx 5 seconds The UPS switches off immediately in the event of a short circuit on the output s...

Страница 22: ...and switching off is performed by the operator In addition data can be exchanged via the communications interface but this is not absolutely necessary for the general operation of the equipment 9 2 1...

Страница 23: ...6 Wait a few seconds refresh 7 Switch the UPS back on switch on the front of the equipment The UPS equipment should revert to on line mode after a few seconds This test ensures that the system will al...

Страница 24: ...r load s are overloading the UPS Remove the consumer or some of the consumers from the UPS The bridging time is less than the rated value The batteries are not fully charged or individual batteries ar...

Страница 25: ...it our Internet home page http www effekta com The following basic functions are supported by all software packages o Detection and display of the UPS mains power status o Display of the UPS output st...

Страница 26: ...time support time Before starting this procedure it is absolutely essential to save all open data Also inform all employees concerned There are essentially two methods of measuring the support time M...

Страница 27: ...0 500 600 650 800 Instruction Manual ME series Page 27 of 32 13 2 Service log Enter all maintenance and servicing work performed on the UPS equipment into the service log Date Work carried out Carried...

Страница 28: ...ffekta com html kontakt html 13 4 Maintenance and service contracts EFFEKTA Regeltechnik GmbH offers you tailored maintenance and customer services that ensure the highest possible reliability and ava...

Страница 29: ...d voltage support mode 230V AC modified sine 15 Max output current 1 7A 2 1A 2 6A 2 8A Bridging time 6 min 6 min 4 min 4 min Efficiency AC AC 94 DC input Input voltage 12V DC rated Interface LAN RS232...

Страница 30: ...d Interface LAN RS232 9 pin D SUB socket or USB galvanically isolated Environmental data Perm temp range 0 40 C Recommended temp 15 25 C Storage temperature 0 40 C Rel atmos humidity 0 90 non condensi...

Страница 31: ...y the warranty for this UPS Wearing part Function Item number XXXX XX XX Battery 12V 7Ah ME400 ME500 ME600 ME650 energy accumulator Depending on equipment see accessories or on request XXXX XX XX Batt...

Страница 32: ...EC for devices operating within a restricted voltage range 93 EEC supplement to guideline 73 23 EEC 89 336 EEC guideline on electromagnetic compatibility 92 31 EEC supplement to EMC guideline 89 336 E...

Отзывы: