pLeASe NOTe: the information in the table below and the action to take is intended for
the use of the assistance centre personnel and others qualified to install/maintain the
equipment.
error message
meaning
error
Cause
Solution
Critical errors
No software dialogue
with an element alre-
ady recognised.
Lack of
communication with
1 or more devices.
One of the devices is
not receiving power
or is not connected.
1. Check the device
connections.
2. Run the start-up
sequence.
The control panel is
not in dialogue with
the other electronic
elements.
Lack of
communication with
1 or more devices.
One of the devices is
not receiving power
or is not connected.
1. Check the device
connections.
2. Run the start-up
sequence.
New peripheral device
recognised.
A new component
has been connected
to the product.
1. Check connections
and power cabling.
2. Run the start-up
sequence.
Temperature probe is
broken.
Problem with the
probe.
Replace panel.
Non-critical errors
Boiler full too soon.
The boiler filled
too quickly during
initial rinsing or final
emptying.
Outlet valve not
working.
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or is
not siphoning.
3. Clean the outlet
valve.
Boiler not yet full.
The boiler didn’t fill
within the prescribed
time limit during
initial rinsing or final
emptying.
Lack of water in the
system or the inlet
valve filter is blocked.
1. Check that the
water tap is turned
on.
2. Check that there is
water in the system.
3. Check that the
filter at the entrance
to the inlet valve is
not blocked.
Boiler not yet empty.
The water level in
the boiler remained
too high for too long
during initial rinsing or
final emptying.
Outlet valve not
working.
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or is
not siphoning.
3. Clean the outlet
valve.
For any situations not covered in this table, consult your approved assistance centre or contact the company
direct.