Operating voltage *) **):
12 – 24V DC STAB (-10%, +15%)
Current **):
Max. 0.40 A
Idle 0.13 A (12V DC)
0.065 A (24V DC)
Micro switches **):
Max. 0.5 A 30V AC/DC resist.10 W
Operating temperature:
-20°C - +60°C
Bolt throw:
20 mm (deadbolt), 10 mm (double action bolt)
Backset:
55, 60, 65 mm (wooden style)
30, 35, 40, 45 mm (narrow style)
Forend:
20, 24 mm (wooden style)
24, 28 mm (narrow style)
Spindle:
9 mm (8 mm with snap spindle adapter)
Connection cable:
Z09XKAB (10 m) 16 x 0.14 mm
2
Door clearance:
2 - 5.5 mm
Settable functions:
Mechanical functions:
- Opening direction of trigger bolt
- Exit handle side (709X)
Electrical function: *) **)
- Fail locked / Fail unlocked
Monitoring outputs **):
Bolt deadlocked
Lock open
Trigger bolt in
Handle down
Cylinder used
Sabotage
Strike plate:
Z09XSBL-01 ... Z09XSBL-04
*) Not micro switch locks
**) Not mechanical locks
TECHNICAL DETAILS
TESTED ACCORDING TO THE STANDARDS
EN 179
3 7 6 1 1 3 4 2 A
Exit
EN 1125
3 7 6 0 1 3 2 1/2 A
Panic exit
EN 1634-1
Fire
EN 61000-6-1:2001
EMC
EN 61000-6-3:2001
EMC
EN STANDARDS
ENGLISH
TIP!
Remove exit handle Allen screw of split spindle lock case to enable electrical
controlling of both handles (through spindle lock function). In this case, remove or
cover also the CE mark label.
4
Содержание 309X
Страница 14: ...709X Rohrrahmen 709X Rohrrahmen ÄNDERN DER STEUERFALLENPOSITION Federn in den Steuerfallenbolzen ASSA ABLOY 14 ...
Страница 20: ...A B C C1 C2 20 ...
Страница 21: ...D D1 D2 E E1 E3 E2 2 3 1 4 21 ...
Страница 22: ...F G H H1 H2 1 2 4 5 3 22 ...
Страница 23: ...I I1 I2 J 1 2 4 3 5 6 7 23 ...
Страница 24: ...K L M 24 ...
Страница 25: ...N O 25 ...
Страница 26: ...P Q 26 ...
Страница 27: ...R S 27 ...