EFD ValveMate 6000 Скачать руководство пользователя страница 2

VALVEMATE
6000

Purge

Power

Fuse T  125mA 250V
100/120/220VAC
50/60Hz    18/15 VA

Rear Panel

Initiate
5-24 VDC or
Contact Closure

Initiate

Air Input
70 PSI
(4.8 BAR)
Minimum

Air Output

+

 220

Spare fuse

Voltage value

Cartridge window

(check voltage indicated)

220

120

10

0

Getting Started

❶ 

Mounting.

If appropriate, attach the mounting bracket and install the ValveMate in the desired location.  A panel mount kit #7020501 is available. 

❷ 

Input Power.

Check the voltage label on the input voltage selector cartridge to ensure voltage is set properly.  To change the voltage, remove the voltage

selector from the cartridge and rotate so correct voltage shows through cartridge window.  Reinstall cartridge and snap into position.  Install power cord.

❸ 

Initiate Connection.

The ValveMate 6000 can be initiated by application of 5 to 24 VDC to the (+) and (-) terminals, or closure of mechanical contacts

across the (+) and (-) terminals.  If a solid state device is used for the 5 to 24 VDC initiation, a relay must be used with the relay contacts providing the closure.
(The connector supplied with the unit can be used for either configuration.)  As an alternate method, connection can be initiated with a standard EFD foot
pedal #7016714 (not supplied) plugged into the receptacle. 

❹ 

Air Input Connection.

Connect the ValveMate 6000 to plant air by first installing the EFD five-micron filter regulator #7002002 to your air supply.  

Install the air tee with barb fitting #7016230 in the output of the filter regulator.  A 10-ft 1/4" OD air line is supplied.  Using the barb fitting supplied,
connect one end to the #7016230 air tee.  Connect the other end of the air line by pushing it firmly into the air input connector on the ValveMate 6000.

Set the pressure at the #7002002 filter regulator to 70 psi (4.8 bar).

❺ 

Control Air Output.

Push the male quick-connect on the valve air hose into the air output fitting on the back of the controller and turn clockwise to lock.

Valve Setup.

Follow the setup instructions in the EFD dispense valve operating manual.

Operational Test.

Place a container under the valve outlet.  Turn on air and power.  Press the PURGE button until fluid fills the line and flows from the

valve outlet.  The system is now ready for operation.

Material
Constant air
Pulsed air for valve operation

Black quick-connect

Five micron filter
regulator 
#7002002

 Air tee

#7016230 

Shutoff valve

To exhaust

To pressurize

White quick-connect

Fluid feed hose

752V-UH-SS 
Fluid dispense
valve

ValveMate
6000 controller

Note:  Use only oil-free, 
clean, dry filtered air.

Pressure relief valve

Pressurized reservoir 
with air regulator

20

0

5

 Flexible air line
#7017032

 

Power

 

Purge

VALVEMATE 
6000

(1.0 liter tank shown)

Typical Setup