Features &
Controls: 
Back Panel

11

!

CAUTION:

 

Maximum Input Air Pressure 100 psi (6.9 Bar)
Refer to User's Guide for instructions on proper 
use of this equipment prior to placing into service

Air Input Port 

Push one end of the 6 mm air input hose into the back of the Ultra 870. A standard air
hose is provided.

Connect the other end of the air input hose to your plant air supply.

Note: Clean, dry filtered factory air is required to meet warranty. If your air supply is not filtered,
order the five-micron filter regulator (specify EFD part #2000F755).

Warning!

Bottled nitrogen can be used. If high pressure bottled air or nitrogen is used, a high

pressure regulator must be installed on the bottle and set at 100 psi (6.9 bar) maximum. In this
instance, the 2000F755 filter regulator is not required.

Foot Pedal 

Connect the foot pedal provided to the port on the back of the Ultra 870. The foot pedal is used
to activate the dispense cycle. The ports are color coded to the tubing from the foot pedal.

Vacuum Transducer / Air Exhaust Port 

The vacuum transducer and exhaust port is located on the back panel.

If needed you can connect a cleanroom filter muffler to filter output air to meet Fed 209-B 
(0.5 micron particulates). Specify EFD part #2170FT.

air input 

foot pedal

exhaust / vacuum

Содержание Ultra 870 Series

Страница 1: ...User s Guide Ultra 870 Dispenser Electronic pdf files of EFD manuals are also available at www efd inc com manuals html Ultra 870 A NORDSON COMPANY...

Страница 2: ...0 556 3484 between 8 30 a m and 5 30 p m Eastern time In Europe call 44 0 1582 666334 In Asia call 86 21 5854 2345 In all other areas call your authorized EFD distributor or 1 401 434 1680 The EFD Ple...

Страница 3: ...ringe Barrel 13 Syringe Barrel Loaders 14 Test Procedures 15 Schematic Parts List 16 Troubleshooting 17 Helpful Hints 18 Productivity Tools 19 Warranty Back Cover This manual is for the express and so...

Страница 4: ...on operation and service are not followed Personal Safety To prevent injury follow these instructions Do not operate or service equipment unless you are qualified Do not operate equipment unless safet...

Страница 5: ...ers are located Clean maintain test and repair equipment according to the instructions in your equipment documentation Use only replacement parts that are designed for use with original equipment Cont...

Страница 6: ...00 Weight 0 95 kg 2 08 lb Cycle rate Exceeds 600 cycles per minute Air input 80 to 100 psi 5 5 to 6 9 bar Air output 0 to 100 psi 0 to 6 9 bar Note Specifications and technical details are subject to...

Страница 7: ...uctions in the enclosed Welcome letter to contact your EFD representative Unpack the Unit Warranty 2 Install Barrel Holder 3 Note Clean dry filtered factory air is required to meet warranty If your ai...

Страница 8: ...ap the safety clip on the adapter hose closed to prevent dripping Remember to unsnap the clip when ready to dispense Replace tip cap with an EFD precision dispense tip Place syringe barrel in the barr...

Страница 9: ...9 Getting Started Completed Setup Note Each number corresponds to the appropriate Getting Started step...

Страница 10: ...t off turned completely clockwise do not force Vacuum is required when dispensing thin fluids Turn the knob counter clockwise to the desired vacuum setting See page 12 for details on using the Vacuum...

Страница 11: ...2000F755 Warning Bottled nitrogen can be used If high pressure bottled air or nitrogen is used a high pressure regulator must be installed on the bottle and set at 100 psi 6 9 bar maximum In this inst...

Страница 12: ...FlowTM piston push the white piston down until it comes in contact with the fluid 2 Attach the syringe to the EFD adapter assembly 3 Snap the safety clip tightly closed to prevent any dripping 4 Remov...

Страница 13: ...e syringe barrel is now ready for use Filling procedure for thick fluids If your fluid is thick or non leveling you can spoon it into the syringe barrel with a spatula Or if the fluid comes packed in...

Страница 14: ...p your work area clean save time and reduce the chance of entrapped air in the fluid 1 You could use the EFD 920BL barrel loader Pack the fluid into the 12 ounce cartridge as shown Then place the pre...

Страница 15: ...trolled flow not too fast not too slow 6 Push the air pressure knob in to lock setting 7 Rest the dispense tip on the Dot Standards sheet 8 Press the foot pedal to activate the dispense cycle Release...

Страница 16: ...x 6 mm push in elbow 7 2036 Fitting 1 8 FPT x 1 4 barb 8 2004B Female quick connect 9 4042 Bulkhead stop fitting 4 mm 10 1417 Bulkhead fitting 4 mm 11 1418 Differential union tee 4 6 mm 12 2002SCR Rep...

Страница 17: ...use inconsistency For best results remove all air bubbles Material suck back 1 Use a SmoothFlow piston or LV Barrier to prevent material being drawn into the dispenser 2 Another option is to order the...

Страница 18: ...dly and do not tip the barrel Vacuum may pull fluid into the adapter hose or if the syringe barrel is tipped fluid may flow back into the dispenser 6 Always use new EFD syringe barrels and tips Carefu...

Страница 19: ...ify EFD part 2441 Liquid filter trap Helps to prevent fluid from being sucked back into the dispenser Specify EFD part 1000FLT Y Five micron regulator Required for production areas where clean dry fil...

Страница 20: ...atsoever in connection therewith This warranty is valid only when clean dry filtered air is used EFD makes no warranty of merchantability or fitness for a particular purpose In no event shall EFD be l...

Отзывы: