
Features &
Controls:
Back Panel
11
!
CAUTION:
Maximum Input Air Pressure 100 psi (6.9 Bar)
Refer to User's Guide for instructions on proper
use of this equipment prior to placing into service
Air Input Port
•
Push one end of the 6 mm air input hose into the back of the Ultra 870. A standard air
hose is provided.
•
Connect the other end of the air input hose to your plant air supply.
Note: Clean, dry filtered factory air is required to meet warranty. If your air supply is not filtered,
order the five-micron filter regulator (specify EFD part #2000F755).
Warning!
Bottled nitrogen can be used. If high pressure bottled air or nitrogen is used, a high
pressure regulator must be installed on the bottle and set at 100 psi (6.9 bar) maximum. In this
instance, the 2000F755 filter regulator is not required.
Foot Pedal
Connect the foot pedal provided to the port on the back of the Ultra 870. The foot pedal is used
to activate the dispense cycle. The ports are color coded to the tubing from the foot pedal.
Vacuum Transducer / Air Exhaust Port
The vacuum transducer and exhaust port is located on the back panel.
If needed you can connect a cleanroom filter muffler to filter output air to meet Fed 209-B
(0.5 micron particulates). Specify EFD part #2170FT.
air input
foot pedal
exhaust / vacuum