Dispense Count Mode

Enabling Auto Increment in Dispense Count mode allows the Ultimus V to increase the memory cell
address from the Start Address to the End address based on the number of dispense cycles that occur. 

The Shot variable on the main screen tracks the number of dispense cycles for the current memory
address and resets to zero when the memory cell address advances to the next address.

In Count mode, the Trigger value represents the number of dispense cycles that need to occur before
the current memory cell is advanced to the next location.  The valid range is 00001 to 99999 dispense
cycles.  The total dispense cycle count for the unit is saved and will continue to increment while in Auto
Increment mode.

Time Mode

Enabling Auto Increment in Time Mode will allow the Ultimus V to increment the memory cell address
from the Start Address to the End Address, based on the number of seconds that have elapsed.  

When Time mode is selected, the real time clock becomes a counter that counts, in seconds, from
00000 to 99999.  The counter resets to all zeros when the memory cell address increments.  

In Time mode, the Trigger value represents the amount of time that needs to elapse before the current
memory cell is advanced to the next location.  The valid range is 00001 to 99999 seconds.

Auto Sequence Mode

Enabling Auto Increment in Auto Sequence mode allows the Ultimus V to increase the memory cell
address from the Start Address to the End address based on the number of dispense cycles that occur.   

The Shot variable on the main screen tracks the number of dispense cycles for the current memory
address and resets to zero when the memory cell address advances to the next address.

As in Count mode, the Trigger value represents the number of dispense cycles that need to occur before
the current memory cell is advanced to the next location.  The valid range is 00001 to 99999 dispense
cycles.  The total dispense cycle count for the unit is saved and will continue to increment while in Auto
sequence mode.

Once the trigger value is reached for the End address, the Ultimus V will automatically reset the memory
cell address back to the Start address and continue increasing the memory cell address as before.  The
auto increment alarm will not be set in this mode. 

27

Содержание ULTIMUS V

Страница 1: ...urope 44 0 1582 666334 Asia China 86 21 3866 9006 Sales and service of EFD dispensing systems are available worldwide A NORDSON COMPANY ULTIMUS V High Precision Dispenser Electronic pdf files of EFD m...

Страница 2: ...all 800 556 3484 between 8 30 a m and 5 30 p m Eastern time In Europe call 44 0 1582 666334 In Asia call 86 21 3866 9006 In all other areas call your authorized EFD distributor or 1 401 431 7000 The E...

Страница 3: ...me Pressure and Vacuum 24 Dispense Modes 24 Using Auto Increment Mode 26 Sample Memory Cell Settings 28 Appendix A I O Connector Pin Descriptions 29 Appendix B RS 232 Connection Protocol 33 Replacemen...

Страница 4: ...D MANUAL Read manual for proper use of this equipment Follow all safety instructions Task and equipment specific warnings cautions and instructions are included in equipment documentation where approp...

Страница 5: ...y injury caused by high pressure liquid can be serious If you are injured or even suspect an injury Go to an emergency room immediately Tell the doctor that you suspect an injection injury Show the do...

Страница 6: ...uards doors or covers are intact and automatic interlocks are operating properly Do not bypass or disarm any safety devices Keep clear of moving equipment Before adjusting or servicing moving equipmen...

Страница 7: ...O All Brass Fittings O EIP A EIP B EIP C SJ T11363 2006 O Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part according to EIP A EIP B EIP C is be...

Страница 8: ...99 mm 7 85 in D Weight 3 36 kg 7 lb 6 5 oz with feet Input AC to power supply 100 240 VAC 1 8 Amp 47 63Hz Output DC from power supply 24 VDC 1 66 Amp maximum Internal Voltage 24 VDC Footswitch 24 VDC...

Страница 9: ...cells Scroll or select cells via front panel keypad or external PC PLC control Switching between Steady Timed and Teach modes Front panel Manual Cycle key Teach function Multi level operator lockout A...

Страница 10: ...4 Hose Support Adapter 5 Filter Regulator 6 Power Cord American Plug 7 Foot Pedal Assembly 8 Barrel Holder Sleeve 9 Barrel Holder 10 Ergonomic Barrel Holder 11 Hose Support Locating Washer 12 Fitting...

Страница 11: ...tput Quick Connector Syringe barrel adapter Optimeter connection ESD Jack Standard 0 166 banana jack allows the user to connect grounding for ESD sensitive equipment Numeric Keypad Used to enter setti...

Страница 12: ...er switches which are specifically designed for this application RS 232 Connector DB 9 Male Style Either the front or rear RS 232 port can be enabled at one time The RS 232 port is selected in the Com...

Страница 13: ...f the air input hose into the Air In fitting on the back of the dispenser 2 Connect the other end of the air input hose to the filter regulator supplied with the Ultimus V dispenser Note Input air sho...

Страница 14: ...pedal for the remainder of setup 5 While resting the tip on the paper test surface increase the air pressure by 1 2 psi 069 138 bar using the keypad until you have reached the desired fluid dispensing...

Страница 15: ...barrel which prevents dripping 1 Make sure that you have attached an EFD syringe barrel filled with the fluid intended for dispensing and that the air pressure is set all the way to zero EFD recommend...

Страница 16: ...lue EFD LV Barrier piston available in 3cc 10cc and 30 55cc sizes If you are dispensing an RTV silicone and find that the piston bounces and causes stringing request EFD s assistance in selecting a su...

Страница 17: ...uage in which data will be displayed Refer to Setting Language below The following examples show data being entered manually For instructions on using the PC Interface Software refer to the appropriat...

Страница 18: ...lected Setting the Real Time Clock Highlight SET CLOCK on the Main Menu screen then press the Enter key Press the F3 function key to select 12 hour or 24 hour format then enter the time Note A leading...

Страница 19: ...ve key to save this setting Setting Units of Vacuum Highlight UNITS OF VACUUM on the Main Menu screen then press the Enter key Use the Up Down 8 2 keys to select the unit type Press the F2 Save functi...

Страница 20: ...the settings and return to the Main Menu screen It is also possible to lock out the entire Main Menu so that when the user presses the Menu Function key on the Main screen the Password screen appears...

Страница 21: ...out resetting the password Alarm Options Screen The Alarm Input Signal is the signal that is sensed on the Alarm Input pins of the digital I O connector The dispenser will not allow any dispense cycle...

Страница 22: ...l reset the Pressure Alarm A check mark in the box next to Enable Pressure Alarm Latching indicates the Pressure Alarm Latch is enabled The Auto Increment Alarm will activate when Auto Increment is ac...

Страница 23: ...lay the Baud Rate selection screen Pressing the F2 Save key will store the communications port settings Contrast Control The LCD contrast can be adjusted from 0 to 63 levels As the contrast ratio is a...

Страница 24: ...acuum while in a specific cell will automatically replace the current settings DISPENSE MODES Timed Mode This mode is used when the desired dispense time is known Use the Up Down 8 2 or Left Right 4 6...

Страница 25: ...sed Setting Pressure Pressure must be entered using the numeric keypad Use the Up Down 8 2 and Left Right 4 6 keys to highlight the PRES field Press the Enter key enter the desired pressure and press...

Страница 26: ...matically resets and continues from the start once the end is reached To choose an Auto Increment mode Use the Up Down 8 2 and Left Right 4 6 keys to highlight the AI field Pressing the F1 key will cy...

Страница 27: ...de is selected the real time clock becomes a counter that counts in seconds from 00000 to 99999 The counter resets to all zeros when the memory cell address increments In Time mode the Trigger value r...

Страница 28: ...Decrease the trigger value to 540 9 minutes Cell 4 Increase pressure to 37 psi keep 150 seconds dispense time 0 vacuum Set the trigger value to 540 9 minutes Cell 5 Increase pressure to 45 psi keep 15...

Страница 29: ...C signal appears across these pins An internal 1 2K resistor will limit the Voltage Initiate signal current to 20mA or less The signal can be momentary no less than 10ms or maintained A new dispense c...

Страница 30: ...imit the current through the EOCF circuit to less than 100mA Pin 5 PS 24VDC Power Supply This pin will provide 24 VDC 100mA power to an external load Pin 6 CC Init Contact Closure Initialization This...

Страница 31: ...rom initializing An internal 1 2K resistor will limit the Alarm Input signal current to 20mA or less This signal can be disabled in the Alarm Options LCD screen Pin 9 Alarm Out Alarm Output This is th...

Страница 32: ...ns from activating the Alarm Out signal The circuit is designed to operate between 5 to 24 VDC with a 100mA maximum current Note A resistor should be placed between the external power source and the A...

Страница 33: ...ation device should connect this pin to its RS 232 TX pin Pin 5 Common Ground 1 RS 232 Protocol 1 1 Communication Specifications The RS 232 protocol for the Ultimus V uses the RS 232C standard The Ult...

Страница 34: ...ed below 1 The Host transmits an Enquiry ENQ command to the Ultimus V 2 The Ultimus V receives the ENQ and transmits an Acknowledge ACK back to the host 3 When the Host receives the ACK the Host will...

Страница 35: ...nd packet STX 04 UA C6 ETX for example 4 When the Ultimus V receives the command packet the Ultimus V transmits an A0 command If there was an error in the command packet or the command could not be ex...

Страница 36: ...long If the command does not contain four characters the remaining characters should be the ASCII space character 0x20h The command is transmitted in ASCII characters 1 4 4 Data The Data part follows...

Страница 37: ...the command packet was interrupted and had timed out Format A2 2 2 Download commands These commands are only from the host to the dispenser The dispenser does not return any data 2 2 1 Memory Change...

Страница 38: ...um Set Command This command updates the vacuum value in the memory location specified in the command This command will update the LCD screen to the specified memory location Host Format VH CHcccVvvvv...

Страница 39: ...12 Pressure Units Set Command This command sets the units the dispenser is using to display pressure Host Format E6 uu uu The pressure units 00 PSI 01 BAR 02 KPA 2 2 13 Vacuum Units Set Command This c...

Страница 40: ...mat mm Minutes 0 59 a Hour format 0 AM 1 PM 2 24 Hour Format 2 2 22 Set the Real Time Date Command This command sets the date on the real time clock on the Ultimus V Host Format EC MmmDddYyy mm Months...

Страница 41: ...the Ultimus V Alarms A 1 indicates the alarm feature is enabled A 0 indicated that alarm feature is disabled Host Format EI INiIOoILlPOpPLbAEeAOa i Enable Input Alarm IN o Enable Output of Input Alarm...

Страница 42: ...pppDTttttt ccc The 3 digit memory location from 0 399 The dispenser will automatically limit value to prevent any errors pppp The 4 digit pressure setting excluding the decimal point This is a unitles...

Страница 43: ...0 Host Format E5 Return Format D0VUuu uu The vacuum units 00 KPA 01 Inches H2O 02 Inches Hg 03 mmHg 04 TORR 2 3 7 Total Status Feedback Command This command returns the status and values of the Auto...

Страница 44: ...t is stored in the dispenser D0 is the letter D followed by the digit 0 Host Format E9 Return Format D0SCccccccc ccccccc 7 digit deposit counter Range is 0000000 to 9999999 2 3 10 Real Time Clock Feed...

Страница 45: ...set AR b lockout Alarms Reset AL e lockout Main Menu selection MM f lockout Pressure Unit Menu selection PU g lockout Vacuum Unit Menu selection VU h lockout Language Menu selection LA j lockout Set C...

Страница 46: ...r Ultimus V 7014546 Power Switch Ultimus V 7014547 Power Supply Ultimus V 7014548 Base Manifold Ultimus V 7014549 Main PC Board Ultimus V 7014550 Cable Front RS 232 Ultimus V 7014551 Ultra 2800 Replac...

Страница 47: ...nc com info efd inc com USA Canada 800 556 3484 Europe 44 0 1582 666334 Asia China 86 21 3866 9006 Sales and service of EFD dispensing systems are available worldwide Ultimus V Replacement Parts 4 8 1...

Страница 48: ...nd service of EFD dispensing systems are available worldwide Optimeter Replacement Parts Pin Optimeter 10cc Std 5 Pack 7014561 Pin Optimeter 30cc Std 5 Pack 7014562 Barrel Lock 10cc Optimeter 7014566...

Отзывы: