Note:
Refer to EFD dispenser operating
instructions to control deposit size with
time and pressure.
Do not reuse reservoirs!
Wipe
plunger clean (if necessary) before
installing a new reservoir.
Setup and Operation
Step 1.
Remove reservoir
retainer.
Step 2.
Install dispensing tip on
reservoir. Insert filled reservoir
into retainer and align flange
with slot as shown.
Step 3.
Install retainer and rotate clockwise
to secure. Connect HP4x to EFD
air-powered dispenser. Insert air
quick-connect into air outlet and
turn clockwise to lock.
Changing Tips
Remove tip retaining cap and invert.
Align slot with wings on dispensing tip.
Turn tip retaining cap counterclockwise
to remove tip. Attach a new tip and
tighten tip retaining cap securely.
For parts list, see back cover.
IMPORTANT:
Confirm that a
white piston is between the
fluid and the plunger.
reservoir retainer
air cylinder
plunger
dispensing tip
ULTRA
™
reservoir system
flange alignment
quick-connect
tip retaining cap
Changing Reservoirs
When a reservoir is empty,
the window in the air cylinder
will turn red. Remove reservoir
retainer. Then, remove empty
reservoir and discard.
window