Note: 

Refer to EFD dispenser operating

instructions to control deposit size with
time and pressure.

Do not reuse reservoirs!

Wipe

plunger clean (if necessary) before
installing a new reservoir.

Setup and Operation

Step 1.

Remove reservoir

retainer.

Step 2.

Install dispensing tip on

reservoir. Insert filled reservoir

into retainer and align flange

with slot as shown.

Step 3.

Install retainer and rotate clockwise

to secure. Connect HP4x to EFD

air-powered dispenser. Insert air

quick-connect into air outlet and 

turn clockwise to lock.

Changing Tips

Remove tip retaining cap and invert.

Align slot with wings on dispensing tip.
Turn tip retaining cap counterclockwise

to remove tip. Attach a new tip and

tighten tip retaining cap securely.

For parts list, see back cover.

IMPORTANT:

Confirm that a

white piston is between the
fluid and the plunger.

reservoir retainer

air cylinder

plunger

dispensing tip

ULTRA

reservoir system

flange alignment

quick-connect

tip retaining cap

Changing Reservoirs

When a reservoir is empty,

the window in the air cylinder

will turn red. Remove reservoir

retainer. Then, remove empty

reservoir and discard.

window