![Efco IP1210S Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/efco/ip1210s/ip1210s_operators-instruction-book_2366938028.webp)
28
9 PROBLEMS, CAUSES AND SOLUTIONS
WARNING
• Before undertaking any action, follow the instructions in the
“Switching off”
section. If it is not possible
to restore correct operation of the high pressure cleaner using the information in the table below, contact
a
Skilled Technician
.
PROBLEMS
CAUSES
SOLUTIONS
By setting the switch (2) to
“1”, the water cleaner does
not start.
R e m e m b e r a l s o w h a t
mentioned in the note of
section
«Interrupting the use
(Total Stop)».
A safety device of the system
to which the water cleaner is
connected (fuse, differential
switch, etc.) has triggered.
Reset the protection device.
In case of a new triggering, do not
use the water cleaner and apply to
a
Skilled Technician.
The plug of the power supply cable
is not inserted correctly.
Disconnect the plug from the
socket and reconnect it correctly.
The water cleaner vibrates a lot
and is noisy.
The water inlet filter
(Fig.6)
is dirty. Observe what mentioned in the
section
«Routine maintenance».
The water supply is not enough.
Check that the tap is completely
opened and that the capacity of
the hydraulic network conforms
with what mentioned in the
section
“Features and technical
specifications”.
Insufficient detergent suction. The detergent suction control
device (20) is not correctly set.
Go over the paragraph
“Working
with detergent”.
No detergent in the bottle.
Add detergent
Detergent used is too thick.
Use a detergent recommended
by the manufacturer (see the
detergent chart), diluting it
according to the name plate.
No water comes out from the
nozzle.
Water missing.
Check that the tap of the water
network is completely opened.
Water nozzle clogged.
Clean and/or replace the nozzle
according to what mentioned
in the section
“Features and
technical specifications”.
The water cleaner stops during
the operation.
A safety device of the system
to which the water cleaner is
connected (fuse, differential
switch, etc.) has triggered.
Reset the protection device.
In case of a new triggering, do not
use the water cleaner and apply to
a
Skilled Technician.
The thermal protection device
has cut in.
Observe what mentioned in the
section
“Safety devices”.
Rotating the main switch (2),
the motor hums but does
not start.
The electrical system and/or the
extension are not suitable.
Observe what mentioned in the
section
“Checks and connection
to mains electricity supply”.
Содержание IP1210S
Страница 2: ......
Страница 4: ......
Страница 5: ...2 3 9 8 6 12 1 4 10 7 5 19 20 22 23 L 14 17 24 13 5 4 21 18 11 27 28 11 1 ...
Страница 6: ...C D E G F 2 1 2 A 3 2 ...
Страница 7: ...M N a b 1 2 5 4 6 ...
Страница 187: ......