20
CONNECT THE 2 CIRCUIT SWITCH METERING TO THE NETWORK -
ONLINE
1
ST
STEP
Press
RESET
7 seconds
until all the LEDs are
at half brightness.
2
ND
STEP
Click on
PROG
.
2.1
- The LED
ON
starts to blink, indicat-
ing that it is ready to
be added to the net-
work, during a period
of 10 seconds .
1.1
- The LED
ON
switches on.
3
RD
STEP
Click on the com-
mand button of the
Installation Key (Ref.
40925) in close prox-
imity to the Switch.
3.1
- The LED starts to
blink red, indicating
that it is searching for
the device that is going
to be added.
3.2
- The LED blinks
green and switches off,
the device’s LED
ON
switches off and the
A
,
B
,
D
,
C
LEDs switch on
and off in sequence,
indicating that the
Switch was successfully
added to the network.
Note:
If the Installation Key LED
does not turn green and switch
off, repeat from the 1
st
step.