41
3.4.2 Maximum Temperature setting
Press or to select maximum desired temperature (9,5°C to
35,0°C). Press
OK
to confirm and exit or to go back. (Default
setting: 29,0ºC).
Note: The chronothermostat does not allow the maximum temperature to be
set lower than the maximum temperature, or lower than the temperature set
for Protection against overheating (see 3.6). This setting also serves as a limit
to protect against floor overheating (which is measured via the Floor Probe),
so that the floor temperature does not go exceed the maximum temperature
limits set.
3.5 Calibration (adjust temperature read by the chronothermostat to
real temperature)
Press or to navigate between options (Ambient Sensor or Floor
Probe). Press
OK
to confirm or to go back.
3.5.1 Ambient Sensor
Press or to select the desired calibration (between -3,0°C
and +3,0°C). Press
OK
to confirm and exit or to go back
.
(Default setting: 0,0ºC).
3.5.2 Floor Probe
Press or to select the desired calibration (between -3,0°C
and +3,0°C). Press
OK
to confirm and exit or to go back.
(Default setting: 0,0ºC).
3.6 Antifreeze/Overheating Protection setting
3.6.1 Antifreeze Protection (antifreeze protection temperature can
only be set when in heating mode)
Press or to select desired Antifreeze Protection Temperature
(5,0°C to -0,5°C). Press
OK
to confirm and exit or to go back.
(Default setting: 8,0°C).