6. Cleaning and maintenance
All work in connection with the cleaning,
maintenance and repair of the machine must be
carried out by suitably trained and qualified
personnel who are experienced in this field.
Clean the cutting device with hot water, using a
cloth or sponge.
6.1 Disinfection and cleaning during
operation
The machine is automatically disinfected with hot
water (82 °C) after every processing step during
operation. The disinfection is controlled by the
system control unit. The cleaning unit is supplied by
the system supplier.
For disruption-free operation, ensure that the saw is
always kept clean.
Always comply with the relevant safety and hygiene
requirements (DIN EN 1672)!
Ensure that disinfectants are not brought into
contact with food, whether directly or indirectly.
6.2 Disinfection at shift end
After each shift, the saw must be cleaned and
disinfected.
To do this, select the robot program "Cleaning"
(system provider) and wait until the robot has
reached the cleaning position.
Before carrying out any cleaning or
maintenance work, disconnect the
cutter from the power supply!
Prior to carrying out any
maintenance or repair work,
disconnect the saw from the
connecting flange of the robot. To
prevent injury to hands and face,
the machine must be properly
shut down.
For maintenance work
and when devices are open
Do not add aggressive detergents! Do
not clean with steam or high-pressure
water jet! Do not immerse cutter in
water!
Clean the saw with detergents and disinfectants
approved for this type of equipment, and rinse with
hot water (82°C).
If required, use a high-pressure cleaner to rinse the
saw.
Avoid however spraying water directly onto the
bearing and lubrication points of the machine!
The hot rinsing water cleans and disinfects the saw
blade.
6.3 Cleaning the saw during
maintenance and repair work
1. For maintenance or repair, dismantle the saw
and bring it to your workshop.
2. Remove the blade and clean it.
3. Use a brush and tepid water to remove dirt
(approx. 45...55°C); if necessary, soak the tool
to dissolve encrusted deposits.
4. Add detergent to the warm water. Distribute the
foam evenly over the cleaned surfaces and let
the detergent work for 15...20 minutes.
5. Wipe off the dissolved dirt and rinse the tool
with warm water.
7. Disinfect the saw. Always complete disinfection
as a separate procedure from cleaning! Ensure
that disinfectants are
not
brought into contact
with foodstuffs! Rinse the saw with clean water
and dry it.
Recommended cleaning agents
Diversey Lever Tego 2000: surface-active
disinfectant
Diversey Lever GmbH
Mallaufstr. 50-56, 68219 Mannheim, Germany
Alternative product:
P3-topax 91: surface-active disinfectant
Henkel-Ecolab Deutschland GmbH,
Postfach 13 04 06, D-40554 Düsseldorf,
Germany
For a cleaning schedule and detailed instructions,
contact the above suppliers.
The detergents listed above are recommended
products. If you wish to use other products, you are
obliged to test them as regards suitability and
compliance with the applicable hygiene regulations.
Keep away from the spray range of
the hot water. There is otherwise a
risk of injury from scalding.
Содержание SKR 23
Страница 11: ...Schmid Wezel D 75433 Maulbronn Seite Page 10 14 Ausführung Version 04 2008 4 3 Explosionszeichnung ...
Страница 12: ...Schmid Wezel D 75433 Maulbronn Seite Page 11 14 Ausführung Version 04 2008 4 2 1 Motor kpl ...
Страница 14: ...Schmid Wezel D 75433 Maulbronn Seite Page 13 14 Ausführung Version 04 2008 4 2 3 Maßskizze ...
Страница 15: ...Schmid Wezel D 75433 Maulbronn Seite Page 14 14 14 Ausführung Execution 04 2008 B Konformitätserklärung ...
Страница 26: ...Schmid Wezel D75433 Maulbronn Page Seite 10 14 Version Ausführung 04 2008 4 3 Exploded view ...
Страница 27: ...Schmid Wezel D75433 Maulbronn Page Seite 11 14 Version Ausführung 04 2008 4 2 1 Motor complete ...
Страница 29: ...Schmid Wezel D75433 Maulbronn Page Seite 13 14 Version Ausführung 04 2008 4 2 3 Dimension drawing ...
Страница 30: ...Schmid Wezel D 75433 Maulbronn Page Seite 14 14 14 Version Ausführung 04 2008 B Declaration of conformity ...