Document Name
Document No.
Ver
Date
Page
LIR18650
Specification
ZJQM-RD-SPC-A12112
0.0
2017-8-28
9/9
If the terminals of the Cell become dirty, wipe with a dry clothe before using the Cell.
Storage the cells in storage temperature range as the specifications. After full discharged, we suggest
that charging to 3.6~3.9V with no use for a long time.
Battery should be charged and discharged every 3 months at 0.2 C during long term storage, and then
charge to 50-70% of the capacity for storage.
Do not exceed these ranges of the following temperature ranges
:
Charge temperature range: 0
℃ ~
45
℃
Discharge temperature range: -20
℃ ~
60
℃
Storage temperature range(up to 30 days): -20
℃~
+45
℃
Storage temperature range(up to 90 days): -10
℃ ~
+35
℃
! Special Notice
Keep the cells in
50% charged state
during long period storage. We recommend to charge the
battery up to 50% of the total capacity every 6 months after receipt of the battery and maintain the
voltage 3.6~3.9V. And store the battery in cool and dry place.
EEMB reserves the final explanation. Please use battery strictly according to specification. EEMB will not be responsible for any
inappropriate operation. EEMB keeps the right to change product specifications without previous notice. If any question, please
consult with the manufacturer.