III. ELECTRICAL HOOK-UP

WARNING

BEFORE BEGINNING ANY WORK ON THE ELECTRICAL INSTALLATION,
BE SURE THE SWITCH AT MAIN BREAKER PANEL IS “OFF” TO AVOID

ANY DANGER OF ELECTRICAL SHOCK.

“Three Module, Single Phase” heaters are manufactured to the following specifications:

This unit must have its own independent circuits, using 3 SETS of UL listed 2 conductor and
ground core copper wire cable of the appropriate size protected by 3 separate and independent
correctly rated Double Pole Breakers. (220, 240 V, see Figures 4 and 5). Wire entry into
the unit must be made through the 4 holes provided in the flange on the backplate.

The “live” wires should be connected to the slots in the terminal block marked L1 and L2. The
ground lead must be connected to the slot marked GND. GROUND MUST BE BROUGHT TO

THE “GROUND” AT THE CIRCUIT BREAKER PANEL.

DANGER

FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY.

* Units rated of 240 V can operate at 208 V with reduced output. 

The output will vary in accordance with the following ratios:

208 volts              240 volts   

.75                         1.0

output ratio

volts

MODEL TYPE

OUTPUT / kW

VOLTAGE 

AMPERAGE

EX230

22.5

240

 3 x 32 AMPS

EX280

28.0

240

 3 x 39 AMPS

SPECIAL

3 Separate and independent

correctly rated Double pole

breakers (208/240 Volts)

Figure 4

Figure 5

7

Circuit Breaker Panel

ON

ON

O

FF

OF

F

ON

O

FF

ON

O

FF

ON

ON

O

FF

OF

F

Содержание EX230T2T

Страница 1: ...OPERATE PROPERLY AND IT COULD CAUSE DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE READ ALSO THE ENCLOSED WARRANTY CARD WARRANTY OF THIS WATER HEATER WILL DEPEND ON PROPER INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY WHATSOEVER THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION...

Страница 2: ...08 240V CIRCUITS USING CORRECTLY RATED WIRES AND CIRCUIT BREAKERS WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR CONSULT THE LOCAL ELECTRIC UTILITY FOR FURTHER INFORMATION FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY WARNING WARNING WATER HEATERS EQUIPPE...

Страница 3: ...it weight is approximately 15 lbs Use an appropriate fastener for this weight For the unit to be mounted against hollow walls suggest using steel wall anchors with the correct grip range and 6 32 screw size minimum NOTE The heater should be installed below the level of all hot water outlets serviced by this heater NOTE PRESSURE AND TEMPERATURE RELIEF VALVE These units are not required by UL to hav...

Страница 4: ...MINIMUM 8 CLEARANCE ABOVE UNIT 4 Figure 1A MOUNTING HOLES To 3 Independent circuit breakers serial LUG TERMINALS AT RELAYS ELECTRICAL HOOK UP 208 240 V L1 L2 C B 2 L1 L2 C B 3 L1 L2 C B 1 GROUND LUGS ...

Страница 5: ... tape only No pipe dope NPT Elbow s Union Threaded type Teflon tape only No pipe dope NOTE When soldering pipe joints remove heater from the wall Serious damage can occur if any soldering is done while pipes are connected to the heater Take care to ensure that the pipes are correctly aligned with the inlet and outlet bosses in order to avoid excessive stress on the heater body molding Pipe support...

Страница 6: ...ecting the heater Failure to do so could cause damage to the flow switch 3 Install isolating valves full flow ball valve type on both inlet and outlet pipes This allows unit to be isolated for maintenance purposes Fig 1B 4 When all plumbing is complete fully check the system for water leaks at all the plumbing connections If a leak is present take corrective action Fully open both inlet and outlet...

Страница 7: ... holes provided in the flange on the backplate The live wires should be connected to the slots in the terminal block marked L1 and L2 The ground lead must be connected to the slot marked GND GROUND MUST BE BROUGHT TO THE GROUND AT THE CIRCUIT BREAKER PANEL DANGER FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY Units rated of 240 V can operate at 208 V with reduced output The out...

Страница 8: ...te to ensure all 4 modules to activate GO TO APPROPRIATE SECTION FOR YOUR MODEL NOTE For the following sections the first unit is the right hand heating module and the second unit is the right center far left hand is the forth heating module IV COMMISSIONING YOUR HEATER T2T MODELS a Switch on the power to the first unit The power indicator light should illuminate b Switch on the power to the secon...

Страница 9: ...lsing the unit is modulating the power to achieve the temperature set by means of the temperature adjustment screw ALL HEATERS In order to obtain good control at single lever mixer type faucets single spout the cold water supply to the faucet should be restricted to give approximately the same flow rate of cold water to the faucet as the hot water coming from your Eemax heater The simplest method ...

Страница 10: ...ement 5 ECO TRIPPED High Limit Thermostat TURN OFF THE THREE MAIN CIRCUIT BREAKERS Reset by pushing in red button on each heater module SYMPTOM B NO HEAT OR LOW TEMPERATURE WITH INDICATOR LIGHT ON 1 WATER FLOW TOO HIGH Reduce the water flow by using an outlet ball valve See page 9 for temperature rise at various flow rates 2 INCORRECT POWER SUPPLY Make sure that the unit is connected to the voltag...

Страница 11: ...80 REPLACEMENT HEATER CORE ASSEMBLY EEMAX REPLACEMENT PARTS DIAGRAM CONTROL BOARDS 7 Wire EX 100G EEMAX INC 353 Christian Street Oxford CT 06478 Tel 203 267 7890 11 To 3 Independent circuit breakers serial 8 Wire EX 284 ECO High Limit Thermostat Push to Reset ...

Отзывы: