AD84A01KNXFI01010001.doc
Inwall 8 Input/4 Led Output Module
AD84A01KNX
Product and Application Description
AD84A01KNX module includes 4 digital inputs to interface free
potential contacts; 4 analog / digital inputs for free potential
contacts or temperature sensors and 4 led outputs.
Digital inputs can interface sensors, traditional buttons, etc; 4
led output channels at low voltage can drive LED for synoptics
panels or switches.
Inputs 5 ÷ 8, set as analog inputs, can enable up to 2 tempera-
ture probes (with On/Off threshold) and 2 thermostats to con-
trol heating and cooling equipments, valves, 2 and 4 pipes fan
coils; etc..
The device is equipped with appropriate communication inter-
face with the bus type TP1 (twisted pair) KNX European stan-
dard, according CEI EN 50090.
Application Program
Application Program
Application Program
Application Program
See eelectron website : www.eelectron.com
Maximum number of group addresses:
50
50
50
50
This is the maximum number of different group addresses the
device is able to memorize.
Maximum number of associations:
63
63
63
63
This is the maximum number of associations between com-
munication objects and group addresses the device is able to
memorize.
Caution
Caution
Caution
Caution
: each transmission object has usually associated a
single group address. If you want to associate to a transmis-
sion communication object other addresses in addition to the
first, please note that you can add a maximum of
13
13
13
13
group ad-
dresses of this kind for the whole device.
Technical data
Technical data
Technical data
Technical data
Power Supply:
Via bus EIB/KNX cable
•
Voltage
21..30V DC
•
Current Consumption EIB/KNX
< 10mA
Digital
Digital
Digital
Digital Input
Input
Input
Input 1
1
1
1 –
–
–
– 2
2
2
2 –
–
–
– 3
3
3
3 ---- 4
4
4
4
•
For free potential contacts (dry contacts)
•
Max. length of Connecting Cable:
≤
3
3
3
30 m
0 m
0 m
0 m
(twisted cable)
•
Voltage Scanning: 3,3 V DC (internally Generated)
•
AWG24 cables with 1800 mm length
Digital Input 5
Digital Input 5
Digital Input 5
Digital Input 5 –
–
–
– 6
6
6
6 –
–
–
– 7
7
7
7 ---- 8
8
8
8
•
For free potential contacts (dry contacts)
•
Max. length of Connecting Cable:
≤
10 m
10 m
10 m
10 m
(twisted cable)
•
Voltage Scanning: 3,3 V DC (internally Generated)
•
6 poles terminal with screws.
Analog Input 5
Analog Input 5
Analog Input 5
Analog Input 5 –
–
–
– 6
6
6
6 –
–
–
– 7
7
7
7 ---- 8
8
8
8
•
For NTC temperature probe eelectron code TS01A01ACC
or TS01B01ACC (
measures from
measures from
measures from
measures from ----20°C to +60°C
20°C to +60°C
20°C to +60°C
20°C to +60°C
)
•
Max. length of Connecting Cable:
≤
10 m
10 m
10 m
10 m
(twisted cable)
•
6 poles terminal with screws.
Digital Led O
Digital Led O
Digital Led O
Digital Led Output
utput
utput
utput 9
9
9
9 –
–
–
– 10
10
10
10 –
–
–
– 11
11
11
11 ----12
12
12
12
•
4 outputs for drive led – Max 0,3 mA
•
For LED eelectron code LD00A01ACC or LD00A11ACC
•
AWG24 cables with 1800 mm length
Control Elements
Control Elements
Control Elements
Control Elements
•
EIB/KNX Red LED and button
Mechanical Data
Mechanical Data
Mechanical Data
Mechanical Data
• Case: plastic
• Protection class: II in accordance with EN 61140
• Dimensions: (width x height. X depth.): 43 x 36 x 24 mm
• Weight: approx. 35 g
Electrical Diagram
Electrical Diagram
Electrical Diagram
Electrical Diagram
Electrical Safety
• Degree of pollution (IEC 60664-1): 2
• Degree of protection (EN 60529): IP 20
• Protection class (according to IEC 1140): III
• Overvoltage class (according to IEC 664-1): III
• Bus: safety voltage SELV DC 21…31 V dc
• Meets EN 50090 and IEC 664-1: 1992
EMC Requirements
Complied with EN 50081-1, EN 50082-2 and EN 50090-2.2
Terms of use
• According to EN 50090-2.2
• Ambient temperature during operation: 0 °C + 45 °C
• Storage temperature: - 20 °C + 55 °C
• Relative humidity: max 90%
CE Mark
According to EMC guideline and low voltage directive
Indicators and Control Elements
Indicators and Control Elements
Indicators and Control Elements
Indicators and Control Elements
Wired Connectors:
1.
BLACK
COMMON IN/OUT 1
2.
WHITE
IN 1
3.
YELLOW
OUT 1
4.
BLACK
COMMON IN/OUT 2
5.
RED
IN 2
6.
ORANGE
OUT 2
7.
BLACK
COMMON IN/OUT 3
8.
GREEN
IN 3
9.
BLUE
OUT 3
10. BLACK
COMMON IN/OUT 4
11. VIOLET
IN 4
12. GREY
OUT 4
13. -
IN / TEMPERATURE SENSOR 5
14. -
IN / TEMPERATURE SENSOR 6
15. -
COMMON 5-6
16. -
IN / TEMPERATURE SENSOR 7
17. -
IN / TEMPERATURE SENSOR 8
18. -
COMMON 7-8
19. -
ETS PROGRAMMING SWITCH
20. -
ETS PROGRAMMING LED
21. -
EIB/KNX CONNECTOR
-
BLACK
BUS NEGATIVE
+
RED
BUS POSITIVE
Installation Instructions
Installation Instructions
Installation Instructions
Installation Instructions
The device may be used for permanent indoor installations
in dry locations within wall box mounts.
WARNING
•
Device must be installed keeping a minimum distance
of 4mm between electrical power line (mains) and in-
put cables or red / black bus cable .
•
The device must not be connected to 230V cables
•
The prevailing safety rules must be heeded.
•
The device must be mounted and commissioned by an
authorised installer.
•
The applicable safety and accident prevention regula-
tions must be observed.
•
The device must not be opened. Any faulty devices
should be returned to manufacturer.
•
For planning and construction of electric installations, the
relevant guidelines, regulations and standards of the re-
spective country are to be considered.
Mounting and wiring hints
Mounting and wiring hints
Mounting and wiring hints
Mounting and wiring hints
General Description
The device configuration (KNX physical address assign-
ment) is done by pressing the programming push button.
Please take care during installation to leave connection
wires long enough in order to remove the device easily from
the wall box for commissioning.
Connecting bus cables
•
Connect each single KNX/EIB bus core inside the termi-
nal block observing bus polarity .
•
Slip the bus connection block into the guide slot placed
on the back side of this device and press the block down
to the stop.
Temperature probes
Temperature probes
Temperature probes
Temperature probes
TS01A01ACC
TS01A01ACC
TS01A01ACC
TS01A01ACC
Dimensions in millimetres
NTC resistence tolerance:
± 3%
Measure range
-20°C ÷ +60°C
Cable:
2 wire single insulation
Cable colour:
Black
NTC colour:
Black
Warning
: keep at least 6 mm from all live parts
TS01B
TS01B
TS01B
TS01B01ACC
01ACC
01ACC
01ACC
D1 = 9 mm D2 = 4 mm L2 = 49 mm L1 = 1250 mm
NTC resistence tolerance:
± 2%
Measure range
-20°C ÷ +60°C
Cable:
2 wire double insulation
Cable colour:
White
NTC colour:
White
Warning
: keep at least 3 mm from all live parts
For further information please visit
www.eelectron.com
eelectron spa
Via Magenta 77/22
I-20017 Rho (MI) - Italia
Email: [email protected]
Web: www.eelectron.com