PROBLEM
POSSIBLE CAUSE
SOLUTION
Unit not working
The power is not connected.
Plug into the socket.
The display shows FL.
Empty the unit of water.
In dehumidification mode, the
temperature of the room is too
low.
The unit must be placed in a
room where the temperature is
above 17 °C.
The cooling
effect is not
good
There is direct light.
Draw the curtains.
Doors or windows are open;
there are many people; there are
other heat sources in the room.
Close doors and windows. If
necessary, add an extra air con-
ditioner
The filter is dirty.
Clean the filter or have it re-
placed.
The airways are blocked.
Be sure to remove obstacles.
The unit makes
a noise
The unit is not on a smooth sur-
face.
Place the unit on a hard and flat
surface.
The compressor
does not work
The overheating protection has
been triggered
Wait 3 minutes until the tem-
perature has dropped, and then
restart the unit.
The remote
control does not
work
The distance between the re-
mote control and the unit is too
large.
Decrease the distance and point
the remote control directly at
the unit.
The battery is dead.
Replace the battery.
The unit dis-
plays 'E1' on the
display
The pipe temperature sensor is
wrong.
The pipe-temperature sensor
and the corresponding circuit
requires inspection. Contact
customer service
The unit dis-
plays 'E2' on
the display
The room temperature sensor is
wrong.
The room temperature sensor
and the corresponding circuit
require inspection. Contact cus-
tomer service
9. Technical specifications
Model NORA, Item No.
2525
Recommended working area, m
2
18-35
Cooling capacity BTU/hr
12000 (3520W)
Timer
1-24 hrs
Power supply
220-240 V, 50 Hz
Dehumidification capacity L/day
28
Power consumption (cooling) W
1345
Nominal current A (cooling)
6.0
EER
2,6