RAW ANALOG DATA

The ADC-4U11 will present the raw analog data as a 
number between 0 and 2047* when in 11 bit single 
ended mode and a number between -2048 and 
+2047 when in 12 bit differential mode.

*the usable range with the ADC-4U11 reference
voltage set to 6.144 will be 0 to 1665 in 11 bit single 
ended mode and -1666 to +1665 in differential mode
since the portion of the ranges from (5 volts to 6.144) 
and from (-6.144 to -5 volts) are not usable.

HIGH PRECISION

 

INSTRUMENT AMP

The built-in high precision instrument amplifier utilizes
6 predefined precision voltage references that have 
been selected to provide an exact voltage 
measurement per increment as follows:

256 mv

.125 mv increments (8 per mv)

512 mv

.25 mv increments (4 per mv)

1.024 v

.5 mv increments (2 per mv)

2.048 v

1 mv increments (1 per mv)

4.096 v

2 mv increments (1 per 2 mv)

6.144 v

3 mv increments (1 per 3 mv)

DIFFERENTIAL INPUT IMPEDANCE

at 6.144 volts:

22 Meg ohm

at 4.096 volts:

15 Meg ohm

at 2.048 volts:

4.9 Meg ohm

at 1.024 volts:

2.4 Meg ohm

     at 512 mv:

710 Kilo ohm

     at 256 mv:

710 Kilo ohm

NOTE: 

Once a change is made, the Apply Button will 

appear. Changes will not be applied until you click the 
Apply button. The changes are saved to the 
ADC-4U11.ini file.

Relay and Input labels may be changed by clicking the Relay Control or Input Setup buttons. Click the Analog Setup 
button to make changes to the analog labels, suffix, scale, offset or precision. These also apply to logged data.

The voltage input range may be set by selecting 1 of the 6 possible gain levels using the built in instrument amp.

Start the data logger by checking the Enable box. The logger will roll-over or stop based on the setting in the Max 
Entries box. The Data Interval may be set to minutes or seconds and will log the data based on the setting in the box.

Click the Com Port button to refresh the available Com Ports. Enter or use the pull-down arrow to set the Com Port.

The Sample Rate is the interval between samples (in the example above, the setting is 100 milliseconds or 10 
samples per second).

Check the Start Minimized box to start the ADC-4U11 device driver in "driver only" mode. Blue 4 icon will show in your 
system tray.

Page 12

ELECTRONIC ENERGY CONTROL, INC.

14960 Maple Ridge Rd

Milford Center OH 43045-9016

USA

(937) 349-6000
(800) 842-7714
(937) 349-6000
[email protected]
http://www.eeci.com

PHONE*.................
ORDERS................
TECH SUPPORT...
E-mail*....................
Web*........................
            *International & Domestic

Copyright      2014 - 2022  Electronic Energy Control, Inc.  All Rights Reserved

c

®

Содержание ADC-4U11

Страница 1: ...to detect Maximum Sampling Rate 100 samples per second or better Analog Inputs 4 single ended inputs 11 bit resolution or 2 fully differential inputs 12 bit resolution 11 bit resolution will divide yo...

Страница 2: ...the XP Vista folder if you reconnect your ADC 4U11 to a different USB port a different com port may be assigned Please note that the Microsoft Net Framework must be installed on your system The Net F...

Страница 3: ...uter by clicking on the start button All Programs Windows Update and clicking on Check for updates for XP Service Pack 3 must be installed Step 6 After the ADC 4U11 device driver is installed the ADC...

Страница 4: ...output a 0 to 5 volt or a 0 to 10 volt analog level For additional information on the EX 8M Expansion card please refer the the EX 8M Technical Reference available on the EECI web site THE ADC 4U11 U...

Страница 5: ...or VA 8 instrumentation amplifier The VA 1 connects to any of the analog inputs and will convert a millivolt signal input to a 0 to 5 volt output for input into the ADC Signal levels this low will ma...

Страница 6: ...and the ADC reference AC voltages over 24 volts or great enough to create an electrical shock hazard or fire should be connected to the ADC analog input using a step down transformer to reduce the hi...

Страница 7: ...applied until you click the Apply button The changes are saved to the ADC 4U11 ini file Relay and Input labels may be changed by clicking the Relay Control or Input Setup buttons Click the Analog Setu...

Отзывы: