![Edwards XDD 1 115/230 V Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/edwards/xdd-1-115-230-v/xdd-1-115-230-v_instruction-manual_2366172016.webp)
A746-02-885 Issue A
Page 12
© Edwards Limited 2010. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Installation
Figure 6 - Replacing the motor fuse (dual-voltage motor)
1. Carefully remove the fuse holder at the side of the pump (refer to
, item 5).
2. Replace the defective fuse with a 2.5 A type T and secure the fuse carrier back into its holder.
3.1.2
XDD1 24 V dc
The pump has been factory set to a constant pumping speed when connected to a 24 V DC (=/-10%) supply. The pump
can also be controlled using an external analogue 0-10 V signal. Use a suitable connector mating half (not supplied)
to connect the electrical supplies and your control equipment to the connector on the logic interface cable. When
you make the electrical connections to the XDD 1, refer to
for full details of the logic interface connections.
Table 6 - Logic interface connector pins
Pin number
Signal
Use
2
Control / monitor: 0 V signal
-
4
XDD 1 identity
9
Speed (0-10 V)
To control motor speed
8, 13, 14
Electrical supply: 0 V
Use all pins for connection!
1, 6, 11
Electrical supply 24 V
Use all pins for connection!