background image

edwardsvacuum.com

IG40 BA AND EX LOW PRESSURE 

PASSIVE GAUGES

INSTRUCTION MANUAL

Publication number: D0300030001EN
Issue: B
Original Instructions

Содержание IG40 BA

Страница 1: ...edwardsvacuum com IG40 BA AND EX LOW PRESSURE PASSIVE GAUGES INSTRUCTION MANUAL Publication number D0300030001EN Issue B Original Instructions...

Страница 2: ...as practical we have ensured that the products have been de signed and constructed to be safe and without risks when properly installed and used in accord ance with their operating instructions We ac...

Страница 3: ...cting the bakeable gauge head cable 7 Preparing the gauge head for the connection of the bakeable gauge head cable 7 Connecting the bakeable gauge head cable to the flange on the gauge head 8 Fitting...

Страница 4: ...Dimensions 5 Gauge head connection 8 View onto the gauge head 9 View onto the gauge head 12 List of Tables General gauge head data 4 Bakeable gauge head cable 5 Operating characteristics when used wit...

Страница 5: ...ons in this document Before beginning to work find out whether any vacuum components are contaminated Adhere to the relevant regulations and take the necessary precautions when handling contaminated p...

Страница 6: ...D0300030001EN Safety Page 2 Operate the product with accessories not listed in the corresponding product documentation Subject to technical alterations without prior notice The figures are not binding...

Страница 7: ...ed on the protection cover When communicating with Edwards stating the information on the nameplate is necessary Validity This document applies to products with part numbers Intended use The IG40 BA a...

Страница 8: ...tion Bayard Alpert Extractor system Ambient temperature during operation 20 to 80 C Maximum flange temperature with bakeable gauge cable 250 C Maximum bakeout temperature with no cable connected 400 C...

Страница 9: ...er minute Insulation materials used PTFE PEEK Length 5 10 or 50 m Description IG40 BA IG40 EX Collector potential 0 V Cathode potential 80 V 100 V Anode potential 220 V 220 V Reflector potential 205 V...

Страница 10: ...cal separation is required The gauge heads must not be in direct line of sight of each other Interactions may cause incorrect measurements Table 4 Gauges Description Quantity Gauge 1 Operating manual...

Страница 11: ...se are required when installing the bakeable gauge head cable Positioning of the plug guide is defined through the different bolt diameters on the gauge head Figure 2 item 1 WARNING If during operatio...

Страница 12: ...he gauge head cable are colour coded 3 Bolt the housing Figure 2 item 13 onto the gauge head flange Figure 2 item 1 with the bolts Figure 2 items 5 and 6 and in the case of the IG40 EX only the 3 spac...

Страница 13: ...t Figure 3 View onto the gauge head Note Before connecting Edwards recommends pumping down the system and if possible running a vacuum test or a direct leak search WARNING If during operation the IG 4...

Страница 14: ...EX is not intended to be fail safe WARNING Do not use the IG 40 BA EX to measure the pressure of explosive of flammable gasses or mixtures Note Emission current ie and calibration factor CAL can be f...

Страница 15: ...parts can be detrimental to health and environment Before you begin to work find out whether any parts are contaminated Adhere to the relevant regulations and take the necessary precautions when handl...

Страница 16: ...The cathode should be positioned as parallel as possible with respect to the anode The initially applicable calibration values do not apply any longer after exchanging the cathode Deviations up to 15...

Страница 17: ...scription and item number according to the spare parts list Table 6 Spare parts Accessories Table 7 Gauge head cables Product description Item number Spare cathode IG40 BA D03000309 Spare cathode IG40...

Страница 18: ...riate storage leads to an increase of the desorption rate and or may result in mechanical damage of the product Cover the vacuum ports of the product with protective lids or grease free aluminum foil...

Страница 19: ...rtant for the safety of our employees and all other people involved in the service of your equipment The hazard information also lets us select the correct procedures to service your equipment We prov...

Страница 20: ...e within the scope of the European Directive on Waste and Electronic Equipment 2012 19 EU Edwards offers customers a recycling service for the product cables associated gauge heads at the end of the p...

Страница 21: ...directive as amended by Delegated Directive EU 2015 863 Based on the relevant requirements of harmonised standards EN 61010 1 2010 Safety requirements for electrical equipment for measurement control...

Страница 22: ...omply with the requirements of REACH The product manual provides information and instruction to ensure the safe storage use maintenance and disposal of the product including any substance based requir...

Страница 23: ...This page has been intentionally left blank...

Страница 24: ...P800 80 000 Issue T edwardsvacuum com...

Отзывы: