Introduction

A133-99-880 Issue E

1

Introduction

1.1

Scope and definitions

This manual provides installation, operation and maintenance instructions for the Edwards FL20K Foreline Trap. You 
must use the FL20K as specified in this manual.

Read this manual before you install and operate the FL20K. Important safety information is highlighted as WARNING 
and CAUTION instructions; you must obey these instructions. The use of WARNINGS and CAUTIONS is defined below.

CAUTION

Cautions are given where failure to observe the instruction could result in damage to the equipment, associated 
equipment and process

The units used throughout this manual conform to the SI international system of units of measurement.

1.2

General Description

The FL20K has been developed for use in clean pumping systems to prevent the back-migration of rotary pump oil 
vapour into the systems; we particularly recommend that you use an FL20K with two-stage rotary pumps.

The component parts of the FL20K are illustrated in 

Figure 1

. The FL20K consists of a metal basket (4) located within 

a cast aluminium body (3), the metal basket is secured in place by a knurled nut (1), lid (6) and spring (5).

A sorbent is contained in the metal basket to absorb any oil which back-migrates from the pump. The sorbent 
material used is activated alumina which has exceptional trapping properties for oil vapour. It has a long life (up to 
six months) before it becomes saturated and has to be renewed.

WARNING

Warnings are given where failure to observe the instruction could result in injury or death to 
people.

Содержание FL20K

Страница 1: ...A133 99 880 Issue E Original Instruction Manual FL20K Foreline Trap Description Item Number FL20K A133 05 000...

Страница 2: ...This page has been intentionally left blank...

Страница 3: ...cal data 3 3 Installation 4 3 1 Unpack and inspect 4 3 2 Install the FL20K 4 3 3 Fill the FL20K with sorbent 4 4 Operation 6 5 Maintenance 7 5 1 Replace the sorbent charge 7 6 Storage and disposal 8 6...

Страница 4: ...13 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited Contents Tables Table Page 1 Checklist of items 4 Associated publications Publication title Publication number Vac...

Страница 5: ...oughout this manual conform to the SI international system of units of measurement 1 2 General Description The FL20K has been developed for use in clean pumping systems to prevent the back migration o...

Страница 6: ...All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited Introduction Figure 1 Component parts of the FL20K 1 Nut 2 Wing nut 3 Body 4 Basket 5 Compression spring 6 Lid 7 O ri...

Страница 7: ...ue E 2 Technical Data 2 1 Operating conditions 2 2 Performance 2 3 Mechanical data Figure 2 Dimensions mm Ambient operating temperature range 0 to 50 C Leak tightness 1 bar 1 x 105 Pa differential 1 x...

Страница 8: ...e FL20K as close to the vacuum system and as far from the rotary pump as possible to maximise the useful life of the sorbent When you mount the FL20K ensure that you leave adequate clearance to enable...

Страница 9: ...rests on the end disk 7 Ensure that both end disks 5 and 7 have their smooth side in contact with the balls 6 Refit the washer 10 and end cap 1 over the spindle 7 Refit the second washer 10 and wing...

Страница 10: ...d pump down If the FL20K has been open to atmosphere for a long period of time it may be necessary to carry out prolonged pumping with a gas ballasted rotary pump to remove the absorbed moisture Alter...

Страница 11: ...every three months as a routine maintenance procedure 1 Refer to Figure 1 Unscrew and remove the nut 1 and the lid 6 2 Remove the basket 4 and spring 5 from the trap body 3 3 Refer to Figure 3 Remove...

Страница 12: ...Limited Storage and disposal 6 Storage and disposal 6 1 Storage 1 Return the FL20K to its protective packaging 2 Store the FL20K in clean dry conditions away from direct sources of heat and sunlight 6...

Страница 13: ...tributor When you order please state for each part required Model and Item Number of your equipment Serial Number if any Item Number and description of part 7 2 Spares 7 3 Accessories Description Item...

Страница 14: ...A133 99 880 Issue E Page 10 Edwards Limited 2013 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Отзывы: