B722-40-880 Issue H
Page 14
© Edwards Limited 2018. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
2.9
Podule connector socket
The DX pump has a 2-way Podule Connector Socket in the top of the Podule. When the pump is shipped, this connector
is concealed by a black protective cover. If the connector will be used, this cover should be removed by levering with
a small screwdriver. The mating plug for this connector is supplied with the pump.
The connector is intended to drive a vent valve or fan connected to the two pins. The connector mating plug is shown
in
, with the polarity of the pins marked when the vent valve/fan is energised.
The podule connector plug is available as an accessory, see
Analogue output:
Output voltage
0 to 10 V d.c. (directly proportional to measured
parameter)
Motor speed: 0 - 1500 Hz (0-100%)
Motor power: 0 - 120 W
Motor temperature: 0 - 100 °C
Controller temperature: 0 - 100 °C
Output current
≤
5 mA
NORMAL status output:
Type
Open collector transistor
< Normal speed (default 80%)
Off (2.2 k
Ω
pull up to 12 V d.c.)
≥
Normal speed
On (<0.8 V d.c. sinking 20 mA)
Rating
20 mA to 0 V
FAIL status output:
Type
Open collector transistor
Fail
Off (3.3 k
Ω
pull up to 12 V d.c.)
OK
On (<0.1 V d.c. sinking 1.7 mA,
<0.8 V d.c. sinking 20 mA)
Rating
20 mA to 0 V
*
Mating half of connector not supplied.
Table 8 - Logic interface technical data (continued)
Logic interface item
EXT75DX