background image

C417-80-880

Issue A Original

Instruction Manual

LCPVEK Solenoid Operation Isolation Valves

Description

Item 

Number

Description

Item 

Number

LCPV16EKA 24 V a.c./d.c. Solenoid Valve

C417-80-200 LCPV25EKA 24 V a.c./d.c. Solenoid Valve

C417-90-200

Содержание C417-80-200

Страница 1: ...A Original Instruction Manual LCPVEK Solenoid Operation Isolation Valves Description Item Number Description Item Number LCPV16EKA 24 V a c d c Solenoid Valve C417 80 200 LCPV25EKA 24 V a c d c Solenoid Valve C417 90 200 ...

Страница 2: ...This page has been intentionally left blank ...

Страница 3: ...al environments EN 55011 2009 A1 2010 Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances and fulfils all the relevant provisions of 2004 108 EC Electromagneti...

Страница 4: ...sions of 2004 108 EC Electromagnetic Compatibility EMC Directive 2011 65 EU Restriction of Certain Hazardous Substances RoHS Directive i e The product s contain less than 0 1wt for hexavalent chromium lead mercury PBB and PBDE 0 01wt for cadmium in homogeneous materials subject to the exemptions allowed by the Directive The RoHS Directive does not legally apply to industrial vacuum equipment until...

Страница 5: ...ical data 6 2 5 Product item numbers 6 3 Installation 7 3 1 Unpack and inspect 7 3 2 Install the valve 7 3 3 Electrical connections 7 3 4 Valve coil orientation adjustment 9 4 Operation 10 5 Maintenance 10 6 Storage and Disposal 10 6 1 Storage 10 6 2 Disposal 10 For return of equipment complete the HS Forms at the end of this manual Illustrations Figure Page 1 Dimensions of NW25 valve 4 2 Dimensio...

Страница 6: ...s Limited 2013 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited Contents Tables Table Page 1 General technical data 3 2 Performance data 3 3 Material data 3 4 Electrical data 6 5 Product item numbers 6 ...

Страница 7: ... units of measurement 1 2 Description The solenoid operated valves are designed for general vacuum use where there is a requirement to open and close a vacuum line The vacuum line is opened and closed by a fluoroelastomer pad on the base of the valve plunger which seals against the body of the valve The valve has two ports with NW flanges at 90 degrees to each other and gasses can be pumped in eit...

Страница 8: ...C417 80 880 Issue A Page 2 Edwards Limited 2013 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank ...

Страница 9: ...V25EKA 0 9 kg 0 9 kg Ambient operating temperature 10 to 55 C Storage temperature range 20 to 70 C Vent gas temperature range 10 to 130 C Table 2 Performance data Leak rate Typically 1 x 10 6 mbar litres second Recommended pressure range 1 x 10 6 mbar to 1000 mbar absolute Maximum pressure differential open close 1000 mbar Time to open 20 ms Time to close 50 ms Maximum cycle frequency 600 per hour...

Страница 10: ...C417 80 880 Issue A Page 4 Edwards Limited 2013 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited Technical data Figure 1 Dimensions of NW25 valve ...

Страница 11: ... Edwards Limited 2013 All rights reserved Page 5 Edwards and the Edwards logo are trademarks of Edwards Limited Technical data C417 80 880 Issue A Figure 2 Dimensions of NW16 valve ...

Страница 12: ...c 24 V 50 60 Hz 1 phase or 24 V d c Electrical supply tolerance 10 Duty cycle 100 continuous Enclosure rating IP65 Electrical supply cable outer diameter 6 to 7 mm Electrical supply cable conductor section 1 5 mm2 max Power consumption a c supply Open Hold 72 W 400 ms typically 5 W Power consumption d c supply Open Hold 72 W 50 110 ms typically 5 W Table 5 Product item numbers LCPV16EKA 24 V a c d...

Страница 13: ...numbers in brackets and use the following procedure to connect the electrical supply to the valve ensure that you use a suitable size electrical supply cable Refer to Section 2 4 1 Ensure that the electrical supply corresponds with the voltage stated on the valve label 2 Undo the cover retaining screw 1 3 Gently prise the electronic actuator cover 2 from the electronic actuator 3 4 Unscrew the gla...

Страница 14: ...s to the terminals 4 9 Replace the electronic actuator cover 2 on the electronic actuator 3 and replace the cover retaining screw 1 10 Slide the gland compression ring 9 rubber cable gland 8 cable grip 7 and compression nut 6 down the cable and screw the compression nut 6 onto the electronic actuator 3 to a maximum torque of 2 5 Nm 11 Screw the electronic actuator 3 to the valve 5 using the retain...

Страница 15: ...ientation 1 Ensure that the power supply to the valve is switched off before attempting to adjust the valve coil orientation 2 Remove the coil retaining nut 1 from the valve 3 Rotate the valve coil 2 about the armature tube 3 to the required orientation 4 Replace the coil retaining nut 1 5 Tighten the coil retaining nut 1 to 15 Nm so that the coil 2 is securely pressed against the o ring 4 Figure ...

Страница 16: ...cks when you maintain your vacuum system Check that the connection to the vacuum system is secure Check that the electrical connections are secure and that the electrical cable is not damaged 6 Storage and Disposal 6 1 Storage Place protective covers over the valve ports and store the LCPVEKA valve in cool dry conditions until required for use When required prepare and install the valve as describ...

Отзывы: