Installation
3. Remove the strain-relief nut (6) and sealing gland (5). Pass the electrical supply cable through the strain-relief
nut (6), the sealing gland (5) and into the electrical supply socket (3).
4. Connect the electrical supply cable to the appropriate terminals of the connector block (7, 8, 9) as shown in
5. Push the connector block (2) back into the electrical supply socket (3), a click should be heard; ensure that it is
orientated correctly so that the sockets mate with the corresponding pins on the valve.
6. Tighten the strain-relief nut (6) and push the electrical supply socket (3) onto the three connector pins on the
valve.
7. Refit the retaining screw (4) and tighten; ensure that there is a slight compression of the sealing gasket (1).
Figure 2 - Electrical supply socket
1.
Sealing gasket
4. Retaining screw
7.
Supply (-ve/N or +ve/L)
2.
Connector block
5. Sealing gland
8.
Earth
3.
Electrical supply socket
6. Strain-relief nut
9.
Supply (+ve/L or -ve/N)