INSTALLATION
B756-50-880 Issue C
3
INSTALLATION
3.1
Unpack and inspect
Take care when unpacking the pump to avoid excessive shocks. Excessive shocks could damage the bearings and
reduce the life of the pump. The pump is supplied with the inlet and outlet sealed with plastic covers to prevent
entry of dust and vapour. Do not remove these seals until the pump is installed on the vacuum system.
Fold down all outer cardboard packaging and check the pump. If the pump is damaged, notify the supplier and the
carrier in writing within three days. State the Item Number of the pump together with the order number and the
supplier's invoice number. Retain all packing materials for inspection. Do not use the pump if it is damaged.
Figure 2 - Opening procedures for packaging
Refer to Unpacking/Lifting instructions P400-40-300 supplied before attempting to remove the system from the
packaging.
Check that the package contains the items listed in
. If any of these items is missing, notify the supplier in
writing within three days.
WARNING
Use gloves when handling the pump chamber to prevent skin contact with the Alocrom 1000
coating.