Edwards A505-23-825 Скачать руководство пользователя страница 17

© Edwards Limited 2008. All rights reserved. 

Page 13

Edwards and the Edwards logo are trademarks of Edwards Limited.

Service and spares

A505-23-880 Issue D

5

Service and spares

5.1

Introduction

Edwards products, spares and accessories are available from Edwards companies in Belgium, Brazil, Canada, France, 
Germany, Hong Kong, Italy, Japan, Korea, Switzerland, United Kingdom, U.S.A and a world-wide network of 
distributors. The majority of these centres employ Service Engineers who have undergone comprehensive Edwards 
training courses.

Order spare parts and accessories from your nearest Edwards company or distributor. When you order, state for each 
part required:

Model and Item Number of your equipment

Serial number

Item Number and description of part.

5.2

Service

Edwards products are supported by a world-wide network of Edwards Service Centres. Each Service Centre offers a 
wide range of options including: equipment decontamination; service exchange; repair; rebuild and testing to factory 
specifications. Equipment which has been serviced, repaired or rebuilt is returned with a full warranty.

Your local Service Centre can also provide Edwards engineers to support on-site maintenance, service or repair of 
your equipment.

For more information about service options, contact your nearest Service Centre or other Edwards company.

5.3

Spares

The Service Kit contains all items that you may need to replace on the Oil Drain Kit. Replace items as necessary when 
you do the annual overhaul of the RV pump.

Spare

Item Number

Service Kit

A505-23-825

Содержание A505-23-825

Страница 1: ...23 880 Issue D Original Instruction Manual EMF Adjustable Gas Ballast Oil Drain Kit for RV3 to RV12 Pumps Description Item Number EMF adjustable Gas Ballast Oil Drain Kit for RV3 to RV12 Pumps A505 23...

Страница 2: ...This page has been intentionally left blank...

Страница 3: ...Fit the Oil Drain Kit 3 2 3 Select the gas ballast flow rate optional 5 3 Maintenance 9 4 Storage and disposal 11 4 1 Storage 11 4 2 Disposal 11 5 Service and spares 13 5 1 Introduction 13 5 2 Servic...

Страница 4: ...This page has been intentionally left blank A505 23 880 Issue D Page ii Edwards Limited 2007 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited...

Страница 5: ...er which operates continuously with gas ballast switched on You cannot use the Oil Drain Kit if you want to introduce a purge gas into the RV pump If you want to introduce a purge gas into the RV pump...

Страница 6: ...A505 23 880 Issue D Page 2 Edwards Limited 2008 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 7: ...allow it to cool to a safe temperature Isolate the pump from the electrical supply so that it cannot be operated accidentally 2 Remove the drain plug from the oil mist filter and drain the oil from th...

Страница 8: ...d Edwards and the Edwards logo are trademarks of Edwards Limited Installation Figure 1 Side view pump inlet flange omitted for clarity 1 EMF Oil mist filter 2 Hose clip 3 Flexible oil return tube 4 No...

Страница 9: ...have used the Oil Drain Kit you must switch off the pump al low it to cool and iso late it from the elec trical sup ply be fore you use the fol lowing pro cedure The Oil Drain Kit is supplied configu...

Страница 10: ...select high gas ballast flow equivalent to the gas ballast control on the pump in position II turn the restrictor plate so that the two indentations 3 are aligned with the indentation 4 on the oil ret...

Страница 11: ...nd the Edwards logo are trademarks of Edwards Limited Installation A505 23 880 Issue D Figure 3 Parts sectional view of the oil return assembly 1 Screw 2 Air inlet 3 Restrictor plate 4 Expansion chamb...

Страница 12: ...A505 23 880 Issue D Page 8 Edwards Limited 2008 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 13: ...re the restrictor plate 3 and remove the plate from the oil return assembly 3 Use a suitable tool to remove the blockage from the air inlet 2 4 Refit the restrictor plate 3 to the oil return assembly...

Страница 14: ...A505 23 880 Issue D Page 10 Edwards Limited 2008 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 15: ...ue D 4 Storage and disposal 4 1 Storage Store the Oil Drain Kit in cool dry conditions until required for use When required install the Oil Drain Kit as described in Section 2 4 2 Disposal Dispose of...

Страница 16: ...A505 23 880 Issue D Page 12 Edwards Limited 2008 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Страница 17: ...tem Number of your equipment Serial number Item Number and description of part 5 2 Service Edwards products are supported by a world wide network of Edwards Service Centres Each Service Centre offers...

Страница 18: ...A505 23 880 Issue D Page 14 Edwards Limited 2008 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Отзывы: