Maintenance
5.6
Clean the gas-ballast filter
Note:
You may have removed the gas-ballast filter to connect a gas supply or valve to the gas-ballast inlet.
1. Remove the retainer circlip (3).
2. Remove the protective wire mesh (2) and filter elements (1).
3. Wash the wire mesh and filter in a suitable cleaning solution. Allow the wire mesh and filter to dry before
replacing them in the pump.
4. Refit the wire mesh (2) and filter element (1) in the adaptor plate housing and retain with the retainer circlip
(3).
Figure 9 - Remove/replace the gas-ballast filter
5.7
Clean the motor fan-cover and enclosure
If the motor fan-cover and enclosure are not kept clean, the air-flow over the motor can be restricted and the pump
may overheat.
1. Switch off the pump and disconnect it from the electrical supply.
2. Use a dry cloth and a brush to remove dirt and deposits from the fan-cover and enclosure.
5.8
Clean and overhaul the pump
Clean and overhaul the pump as described in the instructions supplied with the clean and overhaul kit
(refer to
1. Filter element
2. Wire mesh
3. Retainer circlip