background image

 

 

Edu-Logger wide range temperature 
logger sensor 900-244 

 
The Edu-Logger wide range temperature sensor can be 
used  for  any  science  experiment  or  activity  which 
requires  accurate  temperature  measurements  such  as 
in  the  fields  of  physics,  chemistry,  biology, 
environmental science, etc. 
 
The  sensor  comes  pre-calibrated  so  you  can  start 
experimentation right out of the box using this guide.  
 
Using  the  wide  range  temperature  sensor  over  other 
temperature sensors has its advantages: 

 

Sensor  accurately  can  measure  between  -200°C 
and 1200°C – can be used in direct flames. 

 

Extremely  durable  with  a  mesh  metal  wire 
coating. 

 
Hundreds  of  possible  experimental  subjects  that  can 
be done with the 900-244 sensors are: exothermic and 
endothermic  chemical  reactions,  heat  of  combustion 
for  different  materials,  metabolism,  heat  and  energy 
transfer,  effects  of  heat  on  enzyme  function,  weather 
studies,  material  thermal  conductance  properties,  and 
many more.   
 
The wide range temperature sensor uses the following 
units of measure: 

 

Celsius:  The  SI  (International  System  of 
Units) unit of temperature. 

Содержание 900-244

Страница 1: ...Edu Logger Wide Range Temperature Logger Sensor Guide 900 244...

Страница 2: ...her temperature sensors has its advantages Sensor accurately can measure between 200 C and 1200 C can be used in direct flames Extremely durable with a mesh metal wire coating Hundreds of possible exp...

Страница 3: ...y into the computer Resident PC software and browser based application can be downloaded for free at www edulab com as well as a full software user guide Note Make sure not to download and install bot...

Страница 4: ...rature sensor will give a live reading in the box to the left of the screen while plugged in 11 To run an experiment and collect data click Run experiment 12 To end data collection early click Stop ex...

Страница 5: ...uick start guide please visit www edulab com 6 The 900 268 indicator lights will flash take no action until the LED to the far left turns blue this can take up to one minute 7 Take your tablet or smar...

Страница 6: ...u have a newer generation 900 268 with the USB icon on the cover this can be used as a 900 213 meaning you can tether the probes directly to the computer using the 900 268 To engage operation in this...

Страница 7: ...the 900 213 module Procedure 1 Connect the wide range temperature sensor directly to the left side of a charged 900 215 module 2 When ready to collect data press the Start Stop button on the wide ran...

Страница 8: ...rature sensor Restoring sensor s factory default settings Procedure 1 Connect the 900 213 to a PC Mac tablet or smart device 2 Connect the wide range temperature sensor to a 900 213 module they direct...

Страница 9: ...F to 2192 F ADC resolution 15 bit Resolution 0 1 C 0 1 F Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Push button switch for Start Stop experiments in off...

Страница 10: ...re calibrated at the factory The built in software in the logger can be upgraded at any time using software The wide range temperature uses a thermocoupler to accurately measure temperatures from very...

Страница 11: ...of direct sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not cover damage of the p...

Страница 12: ...12 Thank you for using Edu Logger W www edulab com E info edulab com V10012013...