7.

 

Click  the  “On-line  experiment”  button;  this  will 
open a graph below. 

8.

 

Click  on  the  “Module  setup”  button  located  on 
the voltage sensor icon in the module window to 
change the sensor's settings if need be. 

9.

 

Click on the "experiment setup" button to change 
the  experiment  settings  if  need  be  (experiment 
duration for example). 

10.

 

The voltage sensor will give a live reading in the 
box to the left of the screen while plugged in. 

11.

 

To run an experiment and collect data, click “Run 
experiment”. 

12.

 

To  end  data  collection  early,  click  “Stop 
experiment”. 

 

Tablet, smart phone device 

 

Materials needed: 
 

 

900-201 Voltage Sensor 

 

900-268 WiFi Module 

 

900-215 Battery Module 

 
Your  voltage  sensor  needs  to  be  connected  to  a  900-
268 module. The 900-268 module will create a closed 
Edu-Logger WiFi network which will stream the Edu-
Logger data to the device of your choosing. Once your 
device  is  wirelessly  connected  to  the  Edu-Logger 
network  you  can  run  experiments  and  collect  data 
through a browser of your choosing. 
 

Procedure: 

 
1.

 

Connect  the  voltage  sensor  directly  to  the  left 
side of a 900-268 module (no wires required). 

2.

 

Connect a 900-215 module to the right side of the 
900-268 module. 

3.

 

Although  not  required,  we  recommend  plugging 
the  900-215  to  an  outlet  using  a  USB  to  mini 

Содержание 900-201

Страница 1: ...Edu Logger Voltage Logger Sensor Guide 900 201 ...

Страница 2: ...or comes pre calibrated so you can start experimentation right out of the box using this guide Hundreds of possible experimental subjects that can be performed with the 900 201 sensor are Fuel cells battery chemistry electrical parallel circuits electrical series circuits and electronics The voltage sensor s measurement units are Volts V The SI derived unit for electrical potential difference acro...

Страница 3: ...edulab com as well as a full software user guide Note Make sure not to download and install both types of software they will conflict on the computer Procedure 1 Install the Edu Logger software 2 Connect the 900 213 module to the PC or Mac 3 Connect the voltage sensor to the 900 213 module they directly plug together Please note no calibration is required for this sensor 4 Open the Edu Logger soft...

Страница 4: ...top experiment Tablet smart phone device Materials needed 900 201 Voltage Sensor 900 268 WiFi Module 900 215 Battery Module Your voltage sensor needs to be connected to a 900 268 module The 900 268 module will create a closed Edu Logger WiFi network which will stream the Edu Logger data to the device of your choosing Once your device is wirelessly connected to the Edu Logger network you can run ex...

Страница 5: ...which matches the 900 268 Module ID found on the back of the 900 268 device Edu LoggerXXXX for example 8 Give your device about 20 seconds to connect to the 900 268 9 Once the device is connected go to your browser and type the website wifi201 com into the URL bar then wait for 30 60 seconds 10 You will see a Control mode icon in the browser click on this icon 11 The browser will then load a new s...

Страница 6: ...this fashion press 3 times on the panel key Repeating this operation will return the unit to WiFi mode Operation with Edu Logger viewer Materials needed 900 201 Voltage Sensor 900 272 Graphic Display Module 900 215 Battery Module Procedure 1 Connect the voltage sensor to the left side of the viewer 2 Connect the 900 215 module to the right side of the viewer 3 The 900 272 will auto detect the sens...

Страница 7: ...n ready to collect data press the Start Stop button on the voltage sensor a red light will turn on for the duration of the experiment 3 To change the experiment settings first connect to your chosen device PC Mac tablet smart device and select the Module setup button For more information on how to change the experiment settings view the quick start procedure section for your chosen device in this ...

Страница 8: ... 900 213 module to a PC Mac tablet or smart device 2 Connect the voltage sensor to a 900 213 module they directly plug together Please note no calibration is required for this sensor 3 Open the Edu Logger software 4 Click the Tools icon 5 Click the Restore sensor s factory defaults on the menu 6 If prompted to clear the graph click either the Off line experiment or On line experiment button whiche...

Страница 9: ... specifications Range and operation modes 20 V ADC resolution 12 bit Accuracy 1 Resolution 0 01 V Max sample rate S sec 3000 Sensor s features Fully digital data Rugged plastic ergonomic case 4 mm plugs for easy connectivity Push button switch for Start Stop experiments in off line mode LED indicator of experiment status blinks while collecting data Pre calibrated sensing equipment Note Edu Logger...

Страница 10: ...nternal flash memory chip and micro controller in each plastic Edu Logger body This technology allows the sensor to collect and then store the digital data in the correct scientific units o C o F Lux ppm for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The sensor is based on very fast high input impedance differe...

Страница 11: ... sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship The warranty is for a period of 3 years from the date of purchase and does not cover damage of the product caused by improper use abuse or incorrect storage Sensors with a shelf life such as ion selective probes have a warranty of 1 year Should you need to act upon the warranty please contact your dist...