Clean  the  window  area  being  tested.   
Dirty  glass  can  affect  the  accuracy  of 
your results.

Place  both  units  of  the  instrument 
together,  back-to-back,  with  no  glass 
between  them.   Allow  the  magnets  to 
help  align  the  two  units,  and  then  turn 
the power on.

Wait  for  the  instrument  to  register  a 
value of 100% on the display, and then 
pull the two instrument halves apart.

Place the reflector unit on the inside of 
the  window  being  tested.    Push  the 
reflector enclosure FIRMLY against the 
window so the suction cups secure the 
enclosure in place.

Place the instrument unit on the exterior 
of the window being tested.  Again allow 
the  magnets  to  help  align  the  two 
instrument halves.

Once the instrument unit is in position, 
momentarily  press  and  release  the 
power  switch  to  view  the  Light 
Transmission results (VLT value).

After registering the VLT value, remove 
the  instrument  from  the  window  and  it 
will  automatically  power  off,  clearing 
your VLT value from the display after a 
short  delay.    Repeat  the  process  from 
Step  1  if  you  would  like  to  confirm  the 
a c c u r a c y   o f   y o u r   p r e v i o u s  
measurement.

OPERATING TIPS

Make sure the two enclosures fit
together properly when you begin.
The edges of the suction cups should 
not be bent or altered in any way.  You
will notice the felt pads on the back
of the enclosures are contoured so they
do not touch the suction cups when
the two enclosure halves are placed
together properly.  

When testing the rear window of automobiles, take notice of the defrost 
lines that are printed on the interior of the window.  Suctions cups will NOT 
stick if they are positioned on the defrost lines.  If you can not find a location 
where both suction cups will miss the defrost lines, rotate the reflector unit 
90 degrees to position both suction cups in between the lines.  

When your instrument is not being used, please store it in the carrying case 
that was included.     This will protect the product and keep it from getting 
damaged or dirty while being stored.  As with any test equipment, we do not 
recommend  storing  the  instrument  in  your  automobile  overnight  during 
extreme temperature seasons.  

If at any time during the operation of the instrument you want to power the 
unit off, press AND HOLD the power switch and the unit will shut off.

OPERATING TIPS . . . Continued

The reflector area must be properly maintained 
in order for the instrument to continue providing
accurate results.  Use compressed air to blow off
any dust that may accumulate over time.  If there
are smudges on the reflector that can not be
removed by air, use a micro-fiber cloth to wipe
the lens clean.  

1. 

2. 

3. 

4. 

5. 

6. 

7. 

KEEP THIS REFLECTOR

AREA CLEAN

TROUBLESHOOTING

Incorrect usage or the encounter of unexpected conditions while testing can 
result in the following ERROR CODES:

E1:

  The measured VLT value is 

LESS THAN

 the allowed percentage.  The 

E1 error may occur if the instrument is not properly aligned with the reflector 
at start-up or during the actual measurement.  It can also occur if you take a 
measurement without placing it on glass, or are holding the instrument away 
from the glass surface or in free air.  To fix this problem, turn the instrument 
off and make sure it is properly aligned with the reflector, with no glass in 
between the two enclosures.   Now turn the instrument on and conduct a 
new test. 

E2:

  The measured VLT value is 

GREATER THAN

 the allowed percentage.    

The E2 error may occur if the instrument is not properly aligned with the 
reflector  at  start-up,  or  placed  against  a  different  surface  other  than  the 
reflector at start-up.   To fix this problem, turn the instrument off and make 
sure it is properly aligned with the reflector, with no glass in between the two 
enclosure.  Turn the instrument on and conduct a new test.

E3:

  The starting value that was obtained on the reflector unit to calibrate the 

device at 100% was different than expected.   Make sure you properly align 
the two enclosures at start-up.   Also make sure the lens of the reflector is 
clean.  Use compressed air to blow off dust, or a micro-fiber cloth to remove 
smudges.