background image

SOLAR TRANSMISSION & POWER MEASUREMENTS

2

2

CHOICE OF (BTU/HR*FT ) OR (W/M )

AUTO-POWER-OFF FEATURE TO CONSERVE BATTERY

MEMBRANE STYLE POWER SWITCH

REAL-TIME READINGS CONTINUALLY UPDATED

DIGITAL TECHNOLOGY WITH EXCELLENT RESOLUTION

MICROPROCESSOR CONTROL

NO ADJUSTMENTS OR CALIBRATIONS NECESSARY

END-MOUNTED SENSOR

SMALL, PORTABLE CONVENIENT SIZE

The Digital "SOLAR TRANSMISSION & POWER METER" incorporates two meters into 

one.  In Power Mode, the meter measures the power per unit area of incident solar 

radiation reaching the meter's sensing area.   In Transmission Mode, the SP2065 is 

able  to  calculate  the  solar  transmission  percentage  associated  with  a  given 

material.   The meter uses a state-of-the-art sensor coupled with microprocessor 

control to achieve an EASY TO READ hand-held meter.  The device may be used to 

measure the solar characteristics of windows, film or other transparent materials.

GENERAL DESCRIPTION:

FEATURES:

MODEL# SP2065

MADE IN THE USA

SOLAR TRANSMISSION 

& POWER METER

LIGHT

SENSOR

 sp2065_120829.cdr

SP2065 WARRANTY

The manufacturer warrants all models of the SP2065 to be free from defects in material and 
workmanship under normal use and service as specified within the operator's manual.  The 
manufacturer shall repair or replace the unit within six (6) months from the original date of 
shipment after the unit is returned to the manufacturers factory, prepaid by the user, and 
the unit is disclosed to the manufacturers satisfaction, to be thus defective.   This warranty 
shall  not  apply  to  any  unit  that  has  been  repaired  or  altered  other  than  by  the 
manufacturer.  The aforementioned provisions do not extend the original warranty period 
of the unit which has been repaired or replaced by the manufacturer.   Batteries are not 
covered by warranty as well as damage caused by over-heating the device.

The manufacturer assumes no liability for the consequential damages of any kind through 
the use or misuse of the SP2065 product by the purchaser or others.  No other obligations or 
liabilities are expressed or implied.  All damage or liability claims will be limited to an amount 
equal to the sale price of the SP2065.

POWER/TRANSMISSION %

SELECTOR SWITCH

POWER

BUTTON

BATTERY REPLACEMENT

CALIBRATION

The SP2065 is powered by a 9 volt battery.  When the battery voltage is getting too 

low to operate the meter, the display will begin blinking.  Once the display begins 

blinking you will want to replace the battery soon.  To replace the battery, turn off the 

power  meter.    Remove  the  battery  cover  near  the  bottom  of  the  meter  and 

replace with a new battery.   Alkaline batteries will provide the longest service, but 

are not required for this product.

This instrument has been calibrated to detect the total incident solar power of the sun.  

The largest incident value of solar power is obtained when the end of the meter faces 

the sun directly.   When the end of the meter does not face the sun, the incident solar 

power  is  reduced  by  the  cosine  curve  of  the  angle  to  the  sun.      Make  sure  the 

transparent materials being tested are reasonably clean.  

This instrument is factory calibrated to a NIST (NATIONAL INSTITUTE OF STANDARDS AND 

TECHNOLOGY) traceable  thermopile and should require no field adjustment.

KEEP THE COMPETITIVE EDGE WITH PRODUCTS FROM

745 Capital Commons Drive

Toledo, Ohio  43615    USA

PHONE: (419) 861-1030   FAX: (419) 861-1031

WWW.EDTM.COM    Email:  [email protected]

UNIT OF MEASURE

INDICATOR LEDS

1.  If taking measurements near a heat lamp, do not place the meter too close to the 

light source.  If the end of the meter begins to feel hot to the touch, it is too close to the 

light source.   Extended periods of heat exposure can cause deformation of the filters, 

resulting in a change in the accuracy of the meter. It is recommended that the heat 

lamp and meter are separated by at least 18 inches (46 cm).

2.   When taking measurements for transmission percentage or comparative tests, it is 

important that the meter is held in the exact same position for both measurements 

(when possible).   Any change in angle or proximity to your light source can adversely 
affect the accuracy of your measurements.  FOR BEST RESULTS, place the meter 

on top 

of a stand (#SP2075).  It is best to leave the heat lamp and meter stationary, while 

sliding  the  glass  sample  in  between  them.    This  will  guarantee  the  most  accurate 

measurements possible.

3.  When performing tests, it is advised to take multiple readings to reduce the amount of 

error that occurs.   Be aware that a changing light source (sun with moving clouds) will 

affect your measurements.

4.  The light sensor is located at the top end of the enclosure.  For the greatest accuracy 

in measurements, this sensor should be directly facing the light source.  DO NOT alter the 

condition of the sensor opening by touching or pushing on the filter.  Any modifications 

or altering of the exterior surface of the white filter WILL affect the calibration of the meter.  

This area should be kept clean at all times.  Compressed air or a lint-free cloth should be 

used to clean the filter surface if it becomes soiled.

5.  Do not attempt to open the enclosure.  Opening the enclosure will void the product 

warranty and affect the calibration of the SP2065 meter.  

HELPFUL OPERATING TIPS

Отзывы: