Edsyn FX225 Скачать руководство пользователя страница 4

TO REPLACE FILTERS 

 
 
 

Filter Access

 
1. Unplug FX225 from main power supply. 
 
2. Lift off Filter lid clear of the filter package and place on a safe surface. 
 
3. Lift out the pre-filter pad which is recessed into the combined filter enclosure. 
 
4. Replace with a new pre-filter.(XF2501) 
 
5. Replace lid and start up Unit. 
 

7. Start up machine and run as normal. 
 
 
 
 
FILTER REPLACEMENT 
 
There are two separate Filters comprising from the base upwards. 
 
(a) Combined Filter - Part Number XF2502 
(b) Pre-Filter            - Part Number XF2501 
 
It may only be necessary to replace the Pre-Filter. 

 

 

 
 