background image

Parts

Page 2 Parts, Maintenance & Trouble Shooting

Pump Performance Depends On an air tight diaphragm, valve assemblies that seal well on the pump inlet and discharge
valve seats and inlet plumbing that is air tight all the way to the point it is submerse in the liquid. If the pump is not pumping
check first for anything blocking the hose. If it is clear then check the pump by:
1. Removing all hose and fittings from the pump.
2. To check the discharge valve assembly and diaphragm put your hand tightly over the pump inlet and pull back on the

handle. You should feel a vacuum suction and if the discharge valve assembly and diaphragm are working properly, you
should not be able to raise thediaphragm all the way. If you do not feel any suction, do the same thing again and listen for
air being sucked in around the diaphragm. If you hear air movement, inspect for loose bolts or warn diaphragm. If you
hear no air movement, remove the discharge chamber and inspect the valve assembly and valve seat. Clean or replace
the valve and clean or resurface the valve seat as appropriate.

3. To check the inlet valve assembly raise the diaphragm; put your hand over the discharge and push forward on the

handle. If the inlet valve is sealing properly, you should feel the pressure against your hand. If you don't, then remove the
inlet chamber and inspect the valve assembly and valve seat. Clean or replace the valve and clean or resurface the
valve seat as appropriate.

4. When you are sure the pump is working properly and the pump still will not pump liquid, check the inlet plumbing for

leaks. Depending on the height above the liquid even one unsealed fitting can prevent liquid from getting to the pump.

PUMPS USED FOR CRITICAL APPLICATIONS SHOULD BE INSPECTED AND TESTED OFTEN

Visually Inspect Pump Inside and Out for Corrosion and Wear. Oil pivot pins. Replace Parts as Required.

Maintenance & Trouble Shooting

P-165AL-30-07 pg. 2

CAUTION

Special Applications - Edson pumps are used for many
diverse applications. Some may require special parts or
maintenance procedure. i.e.. pumping liquid with gasoline
or other fuels requires using Viton diaphragms and valves.
If you have any questions regarding procedures for your
application, call Edson customer service.

146 Duchaine Blvd., New Bedford, MA  02745-1292 Tel. 508-995-9711  Fax 508-995-5021 E-Mail [email protected]

165AL-30-200 Parts:

Key #

Part No.

Description

Qty

1

113N-0

Size 0 Diaphragm - Nitrile

1

2

160-G-107

Valve Assembly

1

3

160-A-1200

3/8"  Sealing Washer - Stainless

2

4

160-B-50A-200

2" Discharge Chamber- Alum.

1

5

160-B-68A

2" Suction Chamber - Alum.

1

6

160-C-186

Side Inlet Pump Base - Alum.

1

7

160-C-4A

Headring Alum.

1

8

160-B-28A

Drive Arm -Alum.

1

9

160-A-1A

Upper Standard - Alum.

1

10

160-A-906

Lower Standard-SS (not visible in drawing)

1

11

160-A-41ST

32" Pump Handle with Grip

1

12

960-A-1315C

Head Ring Pivot Pin

1

13

960-A-1315E

Standard Pivot Pin

1

14

F1/4-1.75-SC

1/4-20 X 1.75 Socket Head Cap Srew Stainless

4

15

F1/4-FN

1/4-20 Nut Stainless

12

16

F1/4-LW

1/4" Lock Washer

4

17

F1/4-1-SC

1/4-20 X 1" Socket Head Cap Screw Stainless

8

18

F3/8-LW

3/8" Lock Washer

2

19

F3/8-1-HH

3/8-16X1" HHCS Stainless

2

20

1/8" X 3/4" Cotter Pin Stainless

4

21

1/4"-20 X 1.5" Carriage Bolts (Not Shown)

4

22

116CB-31

Pump Carry Board

1

23

671FH-200

Flex Hose 2”

20’

24

670ST-200

Hose Clamps 2” Stainless

2

25

156FE-200NY

Quick Clamp Hose Coupling, Female 2”

2

26

158MF-200NY

Quick Clamp Adapter Male QC X FNPT 2”

1

27

157MM-200NY

Quick Clamp Adapter Male QC X MNPT 2”

1

165AL-30-150 Parts:

 same as above except for the following:

Key #

Part No.

Description

Qty

4

160-B-50A-150

1 1/2" Discharge Chamber- Alum.

1

5

160-B-324A

1 1/2" Suction Chamber - Alum.

1

23

671FH-150

Flex Hose 1 1/2”

20’

24

670ST-150

Hose Clamps 1 1/2” Stainless

2

25

156FE-150NY

Quick Clamp Hose Coupling, Female 1 1/2”

2

26

158MF-150NY

Quick Clamp Adapter Male QC X FNPT 1 1/2”

1

27

157MM-150NY

Quick Clamp Adapter Male QC X MNPT 1 1/2”

1

Optional Parts substituted upon request:

1

113H-0

Size 0 Diaphragm - Hypalon

1

1

113V-0

Size 0 Diaphragm - Viton

1

2

160-G-107V

Pump Valve Assembly - Viton

1

10

1

2

3

4

5

6

7

8

9

11

12

13

14

15

17

18

19

20

2

15

17

15 16

20

27

11

22

23

24

25

26

Pump Spares Kits:

Side Inlet Nitrile Pump Spares Kit

Order # 114N-117-120 Includes:

113N-0          Size 0 Diaphragm - Nitrile
160-G-107   Valve Assembly - Nitrile (2)
160-A-1200   3/8"  Sealing Washer - Stainless (2)

Side Inlet Hypalon Pump Spares Kit

Order # 114H-117-120 Includes:

113H-0          Size 0 Diaphragm - Hypalon
160-G-107   Valve Assembly - Nitrile (2)
160-A-1200   3/8"  Sealing Washer - Stainless (2)

Side Inlet Viton Pump Spares Kit

Order # 114V-117-120 Includes:

113V-0          Size 0 Diaphragm -Viton
160-G-107V  Valve Assembly - Viton (2)
160-A-1200   3/8"  Sealing Washer - Stainless (2)

G-107

113H-0

A-1200

Size 0

10.5"

G-107

113

Отзывы: