Ediseja 21 PEU 016 Скачать руководство пользователя страница 16

PEU 016 - USB to 16x Serial Port Extender Unit

8    ORDERING

ORDERING NUMBER POSITION:

                            

               

1     2     3    4     5     6 ............. 19

ORDERING NUMBER:

  

                                

PEU 016 /  

c

 

.

 

c

 

c

 

c

 

c

 

c

 

........

  . 

c

INTERFACE NUMBER POSITION:

          

                  

                                        

1    2     3    ........... 16

 

Power supply :

110 V-220 V DC, 230 V AC .................................................... 5

Master port:

USB ............................................................................................... U

10/100 Base-Tx (ethernet) ............................................................ E

Power supply:

Rserved for future use: ........................................................................ x

Interfaces:

 (number of all interfaces in PEU 016 is up to 16!)

None .................................................................................................................. N or leave empty

RS232 isolated, Rx & Tx support, DB9M connector ................................................................... 2

RS485 isolated, half duplex, DB9F connector ............................................................................ 5

Multimode fiber optic (820 nm) ST connector, pos. logic* (signal -> light ON) ........................... 6

Multimode fiber optic (820 nm) ST connector, neg. logic* (signal -> light OFF) ....................... 6N

Multimode fiber optic (820 nm) SMA connector, pos. logic* (signal -> light ON) ........................ 7

Multimode fiber optic (820 nm) SMA connector, neg. logic* (signal -> light OFF) ................... 7N

* User can set fiber optic logic by opening the device and set jumpers accordingly. 

Example:

PEU 016 / 5 . U . x . 2 . 2 . 5 . 5 . 6 . 6 . 6N . 6N . 6N . 6N . 6N . 6N . 7. 7N . N . N

    has     

- 110 V-220 V DC, 230 V AC power supply

- 2xRS232 with DB9 male connector

- 2xRS485 with DB9 female connector

- 2x MM Fiber Optic ST connector, positive logic

- 6x MM Fiber Optic ST connector, negative logic

- 1x MM Fiber Optic SMA connector, positive logic

- 1x MM Fiber Optic SMA connector, negative logic

Additional accessories (order if needed):

- power supply cable with „schuko“ plug for PEU 016 power supply, 2 m

- RS232 cable to user's device (state the connector & lenght, up to 15 m)

- fiber optic cables (state the connector type & lenght)

- DIN 35 holder (2 pcs) + screws (4 pcs)

Contact:

Ediseja 21 d.o.o.

Tel: 00 386 51 643 411

Stegne 21C

[email protected]

1000 Ljubljana

www.ediseja21.com

Slovenia – EU

Page:

Device:  

Document: 

Code:

Date:

16

PEU 016

User manual PEUMU016

17.08.2020

Содержание PEU 016

Страница 1: ...PEU 016 Device Document Code Date PEU 016 User manual PEUMU016 17 08 2020 PEU 016 USB to 16x Serial Port Extender Unit User Manual...

Страница 2: ...2 FIBER OPTIC LOGIC SETTINGS 8 4 3 USB DRIVERS INSTALLATION 8 4 3 1 VIRTUAL COM PORT DRIVERS 8 4 3 1 1 VIRTUAL COM PORT DRIVERS EXECUTABLE SETUP FOR WINDOWS 8 4 3 2 DLL DRIVERS for advanced users 9 4...

Страница 3: ...ovenia EU Tel 00 386 51 643 411 Email grega flander ediseja21 com www ediseja21 com Copyright Copyright Ediseja 21 2020 All rights reserved Explanation of the symbols Read the instructions Device was...

Страница 4: ...es can result in severe personal injury or property damage Only qualified personnel may work with described devices after being familiar with warnings and safety notices in this paper and other safety...

Страница 5: ...user selectable PEU system is assembled from PEU 016 device and appropriate drivers for multiple operating systems PEU 016 housing is made from inox and intended for 19 rack mounting or surface mount...

Страница 6: ...PEU 016 USB to 16x Serial Port Extender Unit 3 SCHEMATIC Page Device Document Code Date 6 PEU 016 User manual PEUMU016 17 08 2020 Picture 3 PEU 016 schematic...

Страница 7: ...ds reverse step 3 6 then follow the steps 2 4 5 reverse step 2 4 Step 8 attach DIN35 additional holder if needed not included Removing cards for fiber optic logic change follow the steps 1 unscrew 1 u...

Страница 8: ...itional COM port available to the PC Application software can access the USB device in the same way as it would access a standard COM port USB drivers are available for many operating systems Windows...

Страница 9: ...SB cable reboot the computer and repeat previously described procedure 4 3 2 DLL DRIVERS for advanced users D2XX drivers allow direct access to the USB device through a DLL Application software can ac...

Страница 10: ...temperature must be observed Check the device for damage at unpacking If device is damaged it must not be installed but it should be send to the manufacturer for repair The device should be screwed wi...

Страница 11: ...struction must be taken into consideration Device must operate completely assembled Device must be used as described No modifications of the device should be made Attach ground wire before attaching p...

Страница 12: ...oenix 2pin Power Supply Wire crossection 0 5 2 5 mm2 type single or stranded wire voltage rating 500 V colour see valid standard Ground wire crossection Cu 2 5 mm2 colour see valid standard Communicat...

Страница 13: ...ut 1 receiver grey connector Output 1 transmitter white connector Logic interface 6 7 positive light OFF in idle state interface 6N 7N negative light ON in idle state Connector type interface 6 6N ST...

Страница 14: ...re cables must be observed so this type of enclosure ensures additional depth between front side of PEU 016 and cabinet door Bend USB cable holder if it is still too long Page Device Document Code Dat...

Страница 15: ...PEU 016 USB to 16x Serial Port Extender Unit Device Document Code Date Page PEU 016 User manual PEUMU016 17 08 2020 15 Picture 10 Dimensions top side surface mount...

Страница 16: ...logic signal light OFF 7N User can set fiber optic logic by opening the device and set jumpers accordingly Example PEU 016 5 U x 2 2 5 5 6 6 6N 6N 6N 6N 6N 6N 7 7N N N has 110 V 220 V DC 230 V AC powe...