Edin Univox CLS-1 Скачать руководство пользователя страница 6

6

Installation guide for CTC-120 

with microphone for glass or wall

 

Figure 1

Installation and commissioning

1.  Choose a suitable place for the loop driver. Consider that the loop pad, the microphone 

and the loop driver’s power supply will be connected to the driver. If needed, attach the 

wall holder facing upwards on the selected spot. 

2.  Choose a suitable location for the microphone. It can be placed on a wall or on glass. 

When choosing a place for the microphone, consider that the staff shall be able to 

stand or sit and talk in a normal, relaxed way with the listener. An example of how the 

system can be laid out, see fig. 1. Place the microphone cable under the desk in such a 

way that it will reach to where the loop driver/wall holder is mounted. The microphone 

cable is 1.8 meters. 

3.  Mount the loop pad under the reception desk. The loop pad should be attached in the 

angle between the front and the upper part of the reception desk as shown in fig.1 and 

2. This will ensure a constant field distribution with the right direction and also allow 

hearing aid users to tilt their head forwards, for example when writing. When mounting 

the pad (be careful not to damage the loop cables inside the pad), place the loop pad 

cable in such a way that it will reach the loop driver/wall holder. The loop pad cable is 

10 meters.

Microphone

Loop pad

Power supply 
connected to mains

Wall holder and 
loop driver

Содержание Univox CLS-1

Страница 1: ...CTC systems Cross The Counter Loop System Installation Guide...

Страница 2: ...2...

Страница 3: ...rophone installation guide 8 Troubleshooting 10 Measuring devices 10 Univox Listener Univox FSM field strength meter Safety and warranty 11 Maintenance and care 11 Service 11 Trouble shooting 11 Envir...

Страница 4: ...nly requirement for the hearing aids user is to put their hearing aids in T position and for the staff to speak normally into the microphone All Univox drivers have a very high output current capabili...

Страница 5: ...ophone for glass or wall Headphones input Loop pad input Wall holder for loop driver Loop pad M 2 gooseneck microphone Room loop input Line input Mic Line input Microphone sensitivity control Micropho...

Страница 6: ...can be laid out see fig 1 Place the microphone cable under the desk in such a way that it will reach to where the loop driver wall holder is mounted The microphone cable is 1 8 meters 3 Mount the loo...

Страница 7: ...he power supply to mains 5 When all connections are completed correctly the LED indicator for mains power on the right hand side of the front of the driver shall light up The system is now ready to be...

Страница 8: ...suitable place for the microphone It can be placed on a desk or a table When choosing the place for the microphone consider that the staff shall be able to stand or sit and talk in a normal relaxed w...

Страница 9: ...er in the right direction Connect all three cables see page 5 Finally lower the driver into the wall holder and connect the power supply to mains 5 When all connections are completed correctly the LED...

Страница 10: ...mode Also check the status of your hearing aid batteries Bad sound quality Adjust the loop current bass and treble controls Bass and treble adjustment should normally not be needed Make sure that Lis...

Страница 11: ...aintenance and care Under normal circumstances Univox loop drivers do not need any special maintenance Should the unit become dirty wipe it with a clean damp cloth Do not use solvent or strong deterge...

Страница 12: ...www univox eu Hearing excellence since 1965 Univox by Edin the world s leading expert and producer of high quality hearing loop systems created the very first true loop amplifier 1969 Ever since our...

Отзывы: