5. Installation 

(1) Operating Environment 

ER-5390P must be installed and operated within the limits of 

specified operating temperature and humidity (see previous section 
under Specifications). Do not place objects on top of the unit. Do 
not obstruct any vents at the sides of the unit. Do not position the 
hub near any heating source such as heater, radiator, or direct 
exposure to sun. Prevent entering of water and moisture into the unit. 
If necessary, use dehumidifier to reduce humidity. 

(2)  Connecting network devices 

Connect one end of the network cable to any of the RJ-45 or 

BNC connectors on the rear panel, and connect the other end of the 
network cable to the network device with RJ-45 or BNC connector 
and the maximum length between the hub and any network devices 
UTP is 100 meters (300ft) and BNC is 200 meters (650ft). Once the 
network cable is connected on both ends and the attached network 
devices are powered on, the Link Status LED should be lit. 

(3)   Uplink to Another Hub 

The Uplink function is designed to extend your segment by 

connecting to another hub. Note that the Ethernet Hub’s port 1 can 
be switched to an uplink function by switching the sliding switch. 
There are two ways for you to connect to another hub: 

1)  Switch the sliding switch to the uplink mode to convert port 1 to 

an uplink and use a straight-through twisted-pair cable to 
connect port 1 to another hub. 

2) 

If you use a crossover cable to connect the two Hubs, then you 
can use any port on the Ethernet Hub to connect to any normal 
port on the other Hub. Please note: the uplink port must be in 
normal mode for the method to work.

 

 

Содержание ER-5390P

Страница 1: ...8 Port UTP 1 Port BNC 10Mbps Hub ER 5390P User s Manual...

Страница 2: ...rdance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does c...

Страница 3: ...n is designed for connection to another hub to extend your segment rather than a normal port for a workstation For more details about Uplink function refer to the following section Running at 10Mbps w...

Страница 4: ...ate faulty segment isolation Data collision and jabber handling functions 2 Specifications Standards IEEE 802 3 10Mbps Ports RJ 45 x 8 BNC x 1 Uplink Port Slide Switch x 1 Hub LED Power Collision Port...

Страница 5: ...3 Package Contents One Ethernet Hub One External Power Adapter User s Manual POWER COL LNK ACT 9 Port Ethernet Hub 3 2 1 4 5 6 7 8 10Mbps...

Страница 6: ...llision is detected in this segment COL Off No Collision One Lit A valid link is established Flash Data packets received LNK ACT Link Activity Off No link is established One for each port POWER 3 2 1...

Страница 7: ...or and the maximum length between the hub and any network devices UTP is 100 meters 300ft and BNC is 200 meters 650ft Once the network cable is connected on both ends and the attached network devices...

Страница 8: ...he power Connect the output end of the power adapter to the power connector on the rear panel of the hub Connect the power adapter to the power outlet The green Power LED on the front panel of the hub...

Страница 9: ...nnection 3 The first port s Link Status LED is not lit when it is uplinked to another hub Make sure the cable is connected to the uplink port Check the network cable make sure it is properly connected...

Отзывы: