EdilKamin WINDO3 85 Скачать руководство пользователя страница 4

4

ENGLISH

SAFETY INFORMATION

• 

•  Incorrect installations or improper maintenance 

Incorrect installations or improper maintenance 
causes safety risks,for which Edilkamin cannot be 

causes safety risks,for which Edilkamin cannot be 
held liable.

held liable.

• 

•  The product was not designed for use by people, 

The product was not designed for use by people, 
including children, whose physical, sensory or 

including children, whose physical, sensory or 
mental capacities are reduced.

mental capacities are reduced.

• 

•  The product was not designed for cooking.

The product was not designed for cooking.

• 

•  The product was designed to burn dry wood in the 

The product was designed to burn dry wood in the 
quantities and methods described in this manual

quantities and methods described in this manual

• 

•  The product was designed for internal use and in 

The product was designed for internal use and in 
premises with normal humidity

premises with normal humidity

• 

•  For the legal and standard guarantee, refer to the 

For the legal and standard guarantee, refer to the 
Certificate of Guarantee found with the product

Certificate of Guarantee found with the product

• 

•  The product must be installed in premises where 

The product must be installed in premises where 
there is no danger of fire.

there is no danger of fire.

• 

•  In the event of fire, call the competent authorities

In the event of fire, call the competent authorities

• 

•  Do not extinguish the fire with water jets

Do not extinguish the fire with water jets

•  The product must be kept in dry places and not 

exposed to bad weather.

The safety risks can be caused, among other things, 
by:
•  contact with the fire and hot parts (e.g. glass and 

piping). DO NOT TOUCH HOT PARTS and, with 
the product off but hot, always use the glove sup-
plied. Otherwise you risk getting burnt

•  use of unsuitable products for lighting (e.g. al-

cohol). DO NOT LIGHT OR RE-LIGHT THE FLA-
ME WITH LIQUID SPRAY PRODUCTS OR FLA-
METHROWERS. You risk getting seriously burned 
and causing damage to property and people.

•  use of fuel other than dry wood. DO NOT BURN 

RUBBISH, PLASTIC OR ANYTHING OTHER THAN 
DRY WOOD IN THE FIREPLACE. You risk dirtying 
the product, fires in the chimney flue and causing 
damage to the environment.

•  use of fuel different from the recommended fuel. 

DO NOT OVERLOAD THE FIREPLACE. There is 
a risk of deformation with risks for people in the 
event of attempted

•  fixing up and irreversible changes to the colour of 

the paint on the metal parts. Edilkamin or the retai-
ler cannot be held liable.

•  cleaning the hot fireplace. DO NOT EXTRACT 

HOT. You risk compromising the extractor and, 
possibly, smoke in the environment

•  cleaning of the smoke channel with various sub-

stances. DO NOT CLEAN WITH FLAMMABLE 
PRODUCTS. There is a risk of fires, back draft.

•  cleaning of the hot glass with unsuitable products. 

DO NOT CLEAN THE HOT GLASS WITH WATER 
OR SUBSTANCES OTHER THAN GLASS CLEA-
NERS RECOMMENDED OR DRY CLOTHES. The-
re is a risk of cracks in the glass as well as perma-
nent, irreversible damage to the glass

•  deposit of inflammable materials under the safety 

distance indicated on this manual. DO NOT REST 
LINEN ON THE Product DO NOT POSITION THE 
CLOTHES HORSE AT DISTANCES UNDER THO-
SE CONSIDERED SAFE. Keep any form of inflam-
mable liquid far from the appliance in use. There 
is a risk of fire.

•  blocked opening of the air vents in the premises 

or air input. DO NOT BLOCK THE AIR VENT OPE-
NINGS OR BLOCK THE CHIMNEY FLUE. There is 
a risk of a back draft in the room which could da-
mage property and people.

•  use of the product as a support or ladder (DO NOT 

CLIMB ON THE PRODUCT OR USE IT AS A SUP-
PORT). You risk damaging property and people.

•  use of the product with the fireplace open. DO 

NOT USE THE Product WITH THE DOOR OPEN. 
For greater protection of the product, there is a 
spring that allows the product to close automati-
cally.

•  addition of fuel and door opening approaching the 

fire with flammable and loose clothing. Do NOT 
open the door or approach the glass with flam-
mable, wide clothing whose ends could catch fire

•  open the door with incandescent material exiting. 

Do NOT throw incandescent material out of the 
product. You risk a fire

Lastly, you are advised to take all normal precautions 
in relation to home heatingIf in doubt, do not act on 
your own initiative, but contact the retailer or installa-
tion technician.

Содержание WINDO3 85

Страница 1: ...WOOD FIREPLACE UK Installation use and maintenance WINDO3 85...

Страница 2: ...k EDILKAMIN called WINDO3 85 Year of manufacture Ref Data nameplate Declaration of Performance DoP n EK 143 Ref Data nameplate The liability of Edilkamin is limited to the product sup ply only Introdu...

Страница 3: ...m www edilkamin com After unpacking the product check the condition and completeness of the contents In the event of error immediately contact the retailer where the purchase was made providing him wi...

Страница 4: ...OR ANYTHING OTHER THAN DRY WOOD IN THE FIREPLACE You risk dirtying the product fires in the chimney flue and causing damage to the environment use of fuel different from the recommended fuel DO NOT O...

Страница 5: ...wer Power output 13 2 kW Efficiency 84 6 Emissions CO 13 O2 0 095 Temperature of fumes 231 C Minimum draught 5 12 Pa Fuel consumption 3 4 kg h Heatable volume 345 m3 Smoke outlet pipe diameter female...

Страница 6: ...5 2 5 18 18 18 18 2 0 2 0 22 22 18 18 46 46 46 46 87 87 dimensions cm 150 150 53 5 53 5 39 39 56 56 1 5 1 5 14 14 63 63 92 92 28 28 92 92 87 87 51 51 63 63 60 5 60 5 2 5 2 5 18 18 18 18 2 0 2 0 22 22...

Страница 7: ...ey can be adjusted to maximum 10 cm PREPARATION AND UNPACKING The materials composing the packaging are not toxic The materials composing the packaging are not toxic or harmful therefore no particular...

Страница 8: ...de elements BEFORE raising the door Description Number in the figure below Quantity Use Fireplace 1 1 Anti corrosion discs 2 2 dispose of with domestic waste R2 unions 3 2 for ducting in the version w...

Страница 9: ...OOR FRAME INSTALLATION without plates standard with plates added during the installation phase NOT self closing self closing P C D A B B C C A E D DETTAGLIO C SCALA 1 1 N 4 viti DETTAGLIO D SCALA 1 1...

Страница 10: ...tted together have a mainly vertical development no section should have a reserve slope have an inner section preferably circular and however with a ratio between sides lower than 1 5 complete the roo...

Страница 11: ...amber for unburned fuel and any condensate be at least category T400 with an adequate resistance to soot fireIf pre existing it must be cleaned to avoid risk of fire THE CHIMNEY STACK THE CHIMNEY STAC...

Страница 12: ...ng are initially closed and must be opened by removing the pre cut closed and must be opened by removing the pre cut membranes to enable the ambient air to pass through membranes to enable the ambient...

Страница 13: ...sulated case they must be well insulated The channels must have a maximum length of 4 5 m The channels must have a maximum length of 4 5 m each each The said length must be decreased by 1 2 m for The...

Страница 14: ...another but spaced at least 1 cm apart to enable air to flow and prevent heat build up The gather hood to flow and prevent heat build up The gather hood can be made with fireproof panels plasterboard...

Страница 15: ...R OPENING HINGED TYPE OPENING DOOR OPENING HINGED TYPE OPENING Open the two side door wings turning the two spring Open the two side door wings turning the two spring levers on both the wings outwards...

Страница 16: ...air entering the combustion chamber Position Description Effect 1 Ignition maximum power Primary air sent entirely to the hearth Primary air sent entirely to the hearth 2 Intermediate position for nor...

Страница 17: ...flue If the draft is weak initially light a starter fire using If the draft is weak initially light a starter fire using small sized lighting material small sized lighting material Once the correct d...

Страница 18: ...ace the removed ash exclusively in non combustible containers bear in mind that the residual embers may containers bear in mind that the residual embers may still re ignite 24 hours after the last com...

Страница 19: ...l containers with fireproof gloves in the event of a fire ask the authorities for help 5 In case of odours check if If first switch on in this case a paint smell is normal If the product is dirty or d...

Страница 20: ...cod 941326 GB 03 20 H w w w e d i l k a m i n c o m 941326 GB...

Отзывы: