Страница 2: ...i 47 20123 Milan Italy Italian Tax ID VAT NO 00192220192 Hereby declares under its sole responsibility that The pellet stoves mentioned below comply with EU Regulation 305 2011 and the harmonised EU s...

Страница 3: ...nd for anything not specifically indicated in the manual observe local regulations The diagrams provided in this manual are for illustration purposes only they do not always strictly refer to your spe...

Страница 4: ...flue may catch fire and environmental damage may ensue Cleaning the combustion chamber when hot DO NOT CLEAN WITH A VACUUM CLEANER WHEN HOT You could damage the vacuum cleaner and risk the emission of...

Страница 5: ...5 ENGLISH USER INSTALLER DIMENSIONS VYDA2 AIR TIGHT DIMENSIONS cm 8 cm smoke outlet 6 cm combustion air...

Страница 6: ...wer 10 6 3 7 kW Efficiency 92 3 90 8 CO emissions at 13 O2 0 003 0 002 Fumes temperature 152 114 C Fuel consumption 2 3 0 83 kg h Tank capacity 17 kg Draw 11 4 10 Pa Autonomy 7 22 hours Heatable volum...

Страница 7: ...with suitable equipment and in observance of safety regulations Do not turn the package over and handle all parts requiring installation with care PACKAGING details in the cladding paragraph The deliv...

Страница 8: ...IT TO THE PALLET THE DRAWINGS ARE FOR GUIDANCE ONLY USEFUL FOR THE INSTALLATION BUT THEY MAY NOT REFER TO THE SPECIFIC MODEL 1 2 TO REMOVE THE STOVE FROM THE PALLET To remove the stove from the palle...

Страница 9: ...ir from the outside For different countries check if air from the outside For different countries check if there are particular installation conditions allowed for there are particular installation co...

Страница 10: ...some mid point of its length THE FUMES DUCT THE FUMES DUCT Further to the general prescriptions for the fumes duct and flue the fumes duct may not be made of flexible metal material must be insulated...

Страница 11: ...er conditions must be anti downdraught must have an internal cross section equivalent to that of the flue and a fumes outlet at least double that of the interior of the flue for dual flues which shoul...

Страница 12: ...t 80 cm2 diameter 10 cm To prevent draughts we recommend installing the intake behind the product or behind a radiator Installing it in front of the appliance will create unpleasant draughts The air m...

Страница 13: ...o fumi dietro presa aria dietro co uso coassiale Examples of possible installations For the smoke discharge conditions on roof etc check local regulations for sealed pellet stoves rear smoke discharge...

Страница 14: ...lectrical system must be compliant check the operation of the earth in particular Edilkamin is not responsible for malfunctions resulting from an improperly earthed system The power line must be of ad...

Страница 15: ...t or right interchangeable side panels ceramic or stone with metal bracket fitted 3 2 Top ceramic or stone 4 1 INSTALLER 1 3 3 4 2 Small parts M4 screws with washers for securing ceramic parts M6 scre...

Страница 16: ...ide parts and screwed on the top part Fitting of the stone or ceramic front panel above the door 1 To make alignment adjustments between ceramic stone and the door you can use the screws A and B Screw...

Страница 17: ...17 ENGLISH 3 Refit the aesthetic cover CLADDING 3 4 Screw it back with the two screws removed in point 1 aesthetic cover 4 INSTALLER...

Страница 18: ...front 3 Place the top ceramic or stone front panel 2 on the metal support S Fit the front panel 2 using the screws removed previously back view Close the combustion chamber door and check the alignmen...

Страница 19: ...tments between ceramic stone and the door you can move the top or bottom screws of the bracket fixed to the structure The top screws in the slots allow the alignment with the top The bottom screws in...

Страница 20: ...of the stone or ceramic top 4 1 While keeping the top metal plate in a forward position place the top and fit it with the screws underneath For stone top For stone top For ceramic top For ceramic top...

Страница 21: ...first loading of the pellet tank see pellet loading When the stove is hot DO NOT MAKE CONTACT between the pellet bag and the top grille Use the glove when loading the stove while it is operating and...

Страница 22: ...batteries of an incorrect type The remote control has a probe which reads the temperature and communicates with the product for automatic management Day Date and Time DECREASE INCREASE ON OFF switch...

Страница 23: ...the display switches off completely USER DAY AND TIME WARNING Symbols MODE Auto or Timer INFO Bar SET or ALARM or OFF FLAME and FAN Symbols ROOM TEMPERATURE ON OFF INCREASE DECREASE CONFIRM OK MENU AU...

Страница 24: ...and By automatic crono when the desired temperature is reached the product switches off and then back on again when the temperature drops RELAX manual automatic crono enables natural convection mode f...

Страница 25: ...in the cleaning phase START in the Load Pellets and Start 1 phases START in the Start 2 phase with the flame symbol WARM UP in the Warm Up phase with the flame symbol If timer scheduling is active The...

Страница 26: ...the value of T1 T2 or T3 To do so you need to access the Menu The or buttons are disabled The flashing SET or MAN symbol appears the operating Mode symbols and the Power level and Ventilation symbols...

Страница 27: ...symbol appears the operating Mode symbols and the Power level and Ventilation symbols disappear The Set is modified with the or buttons and the setting is confirmed with the button or by waiting 5 sec...

Страница 28: ...in all modes automatic manual and crono Press the button for two seconds to activate the Relax function Activation is indicated on the display with the RELAX symbol instead of the frontal fan Again by...

Страница 29: ...M list displays the buttons have the following functions Active buttons go back to main display go back one level scroll down the AM Menu items select the AM Menu items CRONO FAN STAND BY visible only...

Страница 30: ...king of one of the three temperatures T1 T2 or T3 with a time period DISPLAY CHANGE To access the Crono setting function you must enter the Menu with the button An the first item is CRONO You confirm...

Страница 31: ...mally T1 Night Level 16 C T2 Day Level 20 C T3 Comfort Level 22 C You choose T1 T2 or T3 with going up the Menu and going down the Menu and confirm the item with the button The or buttons are used to...

Страница 32: ...s positioned on the symbol Set The button is used to move the cursor between the Set symbol and the Day of the Week The button is used to go back to the previous display If the cursor indicates the sy...

Страница 33: ...top right the starting time of the time period 00 00 with the cursor below the graphic bar The current Set between OFF and the values of T1 T2 and T3 are displayed bottom centre The or buttons are use...

Страница 34: ...34 ENGLISH USER INSTRUCTIONS CRONO USER to Delete If the Delete action is chosen and confirmed with the button the scheduling is reset...

Страница 35: ...day is chosen on which the scheduling is to be pasted The button is used to confirm the copy action The day on which the action was performed is highlighted and the action can be repeated The button i...

Страница 36: ...36 ENGLISH USER INSTRUCTIONS VENTILATION USER for the ventilation...

Страница 37: ...ure setpoint is reached NOTE visible only if the product is in automatic mode The product is programmed by default with a delta of 1 C to optimise comfort The technician can change this setting during...

Страница 38: ...is not active This function switches the product on off after a set period from activation of the function This is convenient if you go to bed and want the product to switch on off after a few hours 1...

Страница 39: ...e the function in other statuses will not be allowed The function is available only in the OFF status It is not visible in other statuses Status These readings should only be done when requested by th...

Страница 40: ...e fields by moving the cursor forwards The button is used to scroll through the fields by moving the cursor backwards The button is used to save and go back to the previous display Language Selects th...

Страница 41: ...ing pot into which the ash falls 3 Scrape the burning pot with the scraper and clean out any obstructed holes 4 If necessary clean the glass when cold using a dedicated product e g Glasskamin which yo...

Страница 42: ...ASONAL MAINTENANCE to be carried out by the technical assistance centre This consists of cleaning the stove inside and out If the product is used intensively we recommend cleaning the fumes duct and f...

Страница 43: ...ight detonation If white smoke forms in the combustion chamber for a long time disconnect the mains supply and wait 30 minutes before opening the door and emptying out the burning pot TROUBLESHOOTING...

Страница 44: ...on air intake is below the set level Ensure the furnace door is closed Check that the appliance the flue and combustion air conduit are clean H02 Displays when the circuit board is not detecting the c...

Страница 45: ...1 Switching OFF due to the inter vention of the safety pressure switch Ensure the product and flue are clean Contact the technician H12 Room temperature probe failure The product is operating in manua...

Страница 46: ...tion remains at the last display If the lack of communication occurs during navigation through the Menus it automatically goes back to the main display PELLET RESERVE INDICATOR The function is only av...

Страница 47: ...47 ENGLISH...

Страница 48: ...w w w e d i l k a m i n c o m 942270 GB code 942270 GB 03 21 A...