Страница 2: ...R TIGHT SERIAL NO Rating plate reference VYDA AIR TIGHT Performance declaration DoP EK no 161 Moreover the company hereby declares that the VYDA AIR TIGHT wood pellet stoves satisfy the requirements o...

Страница 3: ...to follow the instructions in it could cause serious damage to the product and put the safety of those using it at risk OPERATING SEQUENCE follow the instructions for the operations described Product...

Страница 4: ...the flue may catch fire and environmental damage may ensue Cleaning the combustion chamber when hot DO NOT CLEAN WITH A VACUUM CLEANER WHEN HOT You could damage the vacuum cleaner and risk the emissi...

Страница 5: ...5 ENGLISH USER INSTALLER DIMENSIONS VYDA AIR TIGHT DIMENSIONS cm 8 cm standard smoke discharge 8 13 cm smoke discharge with optional 6 cm combustion air...

Страница 6: ...ssions at 13 O2 0 015 0 056 Fumes temperature 153 94 C Fuel consumption 2 3 0 7 kg h Tank capacity 17 kg Draw 10 10 Pa Autonomy 7 24 hours Heatable volume 260 m3 Fume duct diameter male 80 mm Air inta...

Страница 7: ...ervance of safety regulations Do not turn the package over and handle all parts requiring installation with care PACKAGING details in the cladding paragraph The delivery consists of two packages one 1...

Страница 8: ...IT TO THE PALLET THE DRAWINGS ARE FOR GUIDANCE ONLY USEFUL FOR THE INSTALLATION BUT THEY MAY NOT REFER TO THE SPECIFIC MODEL 1 2 TO REMOVE THE STOVE FROM THE PALLET To remove the stove from the palle...

Страница 9: ...rsuant to Standard 10683 rev 2012 point 6 3 in Italy you can also install the appliance in bedrooms or in rooms which already include a product that takes air from it for combustion provided that the...

Страница 10: ...its length THE FUMES DUCT Further to the general prescriptions for the fumes duct and flue the fumes duct may not be made of flexible metal material must be insulated if routed through unheated areas...

Страница 11: ...ns must be anti downdraught must have an internal cross section equivalent to that of the flue and a fumes outlet at least double that of the interior of the flue for dual flues which should be spaced...

Страница 12: ...s of at least 80 cm2 diameter 10 cm To prevent draughts we recommend installing the intake behind the product or behind a radiator Installing it in front of the appliance will create unpleasant draugh...

Страница 13: ...iale scarico fumi dietro presa aria dietro co uso coassiale scarico fumi sopra presa aria sopra con uso coassiale Examples of possible installations For the smoke discharge conditions on roof etc chec...

Страница 14: ...lectrical system must be compliant check the operation of the earth in particular Edilkamin is not responsible for malfunctions resulting from an improperly earthed system The power line must be of ad...

Страница 15: ...eft or right interchangeable side panels ceramic or stone with metal bracket fitted 3 2 Top ceramic or stone 4 1 INSTALLER 1 3 3 4 2 Small parts M4 screws with washers for securing ceramic parts M6 sc...

Страница 16: ...e side parts and screwed on the top part Fitting of the stone or ceramic front panel above the door 1 To make alignment adjustments between ceramic stone and the door you can use the screws A and B Sc...

Страница 17: ...17 ENGLISH 3 Refit the aesthetic cover VYDA CLADDING 3 4 Screw it back with the two screws removed in point 1 aesthetic cover 4 INSTALLER...

Страница 18: ...he front 3 Place the top ceramic or stone front panel 2 on the metal support S Fit the front panel 2 using the screws removed previously back view Close the combustion chamber door and check the align...

Страница 19: ...ustments between ceramic stone and the door you can move the top or bottom screws of the bracket fixed to the structure The top screws in the slots allow the alignment with the top The bottom screws i...

Страница 20: ...LLER Fitting of the stone or ceramic top 4 1 While keeping the top metal plate in a forward position place the top and fit it with the screws underneath For stone top For stone top For ceramic top For...

Страница 21: ...he pellet tank see pellet loading When the stove is hot DO NOT MAKE CONTACT between the pellet bag and the top grille Use the provided glove when loading the stove while it is operating and hence hot...

Страница 22: ...the result of manual ignition with ignition button request from Crono power request during stand by request from external contact Ignition has a variable duration with the aim of reaching the start t...

Страница 23: ...he type of batteries and the intensity of use Edilkamin and the retailer will not consider claims for battery life under any circumstances If the battery charge is low a warning displays at the top le...

Страница 24: ...menu ON STATE The product is ON The display shows figure 4 1 the current time 2 the current room temperature 3 the room temperature setting or manual mode 4 the power level represented by the flames...

Страница 25: ...ual mode the display reads Man In Automatic mode the temperature displays In automatic Set Room Temperature read by the remote control this should be positioned in the room the product is installed in...

Страница 26: ...oint is reached To access the function from the main menu as indicated in the Menu section above press the M button Scroll using the buttons and select the function by pressing the OK button Use the b...

Страница 27: ...ss the M button LOAD PELLETS STAND BY CRONO NIGHT DATE TIME DISPLAY LANGUAGE BEEP INFO TECHNICAL MENU scroll buttons OK button to confirm The following screen will appear Scroll to ENABLE underlined u...

Страница 28: ...tons Press the OK button to confirm and select SET Press the M button to go back to the previous screen press the OK button to enter the SET function ENABLE TEMP CHANGE SET scroll buttons OK button to...

Страница 29: ...ly Press the OK button to confirm and go to the temperature selection T1 T2 or T3 Press the buttons to switch between the temperatures To continue with other changes press the OK button To choose betw...

Страница 30: ...uring commissioning Available only in the OFF state If you attempt to activate the function in other states access is not granted To access the function from the main menu as indicated in the Menu sec...

Страница 31: ...nfirm by pressing the OK button for 2 seconds Beep Allows you to enable disable the beep To access the function from the main menu as indicated in the Menu section above press the M button Scroll usin...

Страница 32: ...E Before doing any maintenance disconnect the appliance from the mains Regular maintenance is essential to keep the appliance in good working order Failure to service the product properly will prevent...

Страница 33: ...ot into which the ash falls 3 Scrape the burning pot with the provided scraper and clean out any obstructed holes 4 If necessary clean the glass when cold using a dedicated product e g Glasskamin whic...

Страница 34: ...ASONAL MAINTENANCE to be carried out by the technical assistance centre This consists of cleaning the stove inside and out If the product is used intensively we recommend cleaning the fumes duct and f...

Страница 35: ...01 displays when the combustion air intake is below the set level Check that the combustion chamber door is closed Check the regular maintenance of the stove Check that smoke discharge and combustion...

Страница 36: ...itching OFF due to circuit board overheating Contact the technician H11 Switching OFF due to the inter vention of the safety pressure switch Ensure the stove and flue are clean Contact the technician...

Страница 37: ...PLY WARNINGS LOW REMOTE CONTROL BATTERY LEVEL The battery symbol will appear on the remote control display if the battery is low MAINTENANCE A wrench symbol is shown on the display after 2000 hours of...