
- 29
-
ENGLISH
ADVICE FOR POTENTIAL PROBLEMS
In the event of a problem, the stove automatically carries out the shut-down procedure and shows the reason for shut-
down on the display (see the various alarms below).
Never remove the plug during the shutdown phase caused by stoppage.
If stoppage occurs, to restart the stove, allow the shutdown process to take place (15 minutes with
fi
nal beep) and then
press the button.
Reignite the stove only once you have veri
fi
ed the cause of stoppage and RECLEANED/EMPTIED the combustion chamber.
POSSIBLE CAUSES OF STOPPAGE AND INSTRUCTIONS AND SOLUTIONS
A01 Stove does not ignite
(occurs when the smoke temperature during start-up does not exceed the minimum threshold)
• Combustion chamber dirty or too many pellets
• No more pellets
• Chimney
fl
ue obstructed
• Likely faulty electrical resistance
A03 insuf
fi
cient draught
(occurs when the
fl
ow of combustion air falls below the minimum allowable threshold)
• Chimney
fl
ue obstructed
• Door open
• Combustion chamber clogged
• Debimeter (air
fl
ow sensor) dirty
• Door gasket needs replacing
A05 hot smoke
(occurs when the smoke temperature exceeds the established safe temperature)
• Chimney
fl
ue obstructed
• Incorrect installation
• Stove clogged
• Pellet load high, check pellet adjustment (CAT)
A06 No pellets
(occurs when the pellet supply is exhausted; the display
fl
ashes following a “beep” sound)
• No pellets remaining in the hopper
• Gear motor not working
• Pellet inlet channel/ feed screw obstructed
• Pellet load low, check pellet adjustment
A07 smoke sensor broken (occurs when the stove no longer reads the sensor)
• Thermocouple broken
• Thermocouple disconnected
A08 black out (not a defect of the stove)
(occurs if there has been an interruption in power lasting more than 5 seconds)
The stove has a “black out” function.
In the event of a power black out lasting less than 5 seconds, the stove will restart and return to the last function prior to shutdown.
If the black out time exceeds 5 seconds, the stove’s “black out” alarm is triggered, with the resulting cooling phase.
Below is a list of the various possibilities:
Stove status before the black out
Interruption time less than PR
“black out delay”
Interruption time greater than PR
“ black out delay”
OFF
OFF
OFF
PRELOAD
BLACK OUT
BLACK OUT
IGNITION
BLACK OUT
BLACK OUT
START
START
STANDY-BY THEN REIGNITION
OPERATION
OPERATION
STANDY-BY THEN REIGNITION
FINAL CLEANING
FINAL CLEANING
FINAL CLEANING
STAND-BY
STAND-BY
STAND-BY
ALLARM
ALLARM
ALLARM
ALARM MEMORY
ALARM MEMORY
ALARM MEMORY