background image

25

ENGLISH

USER INSTRUCTIONS

REMOTE CONTROL

 

Specifications: 
RF transceiver module, frequency 2.4 GHz - Powered 
by two AAA 1.5 V batteries rated at least 1200 mAh.

ON/OFF button

manual on/off button and for switching the remote 
from energy saving mode to active heating 

touch buttons:
+

: increment button (increases the fireplace’s power, 

temperature or fan speed, etc., or scrolls through the 
menu)

+

: decrement button (decreases the fireplace’s power, 

temperature or fan speed, etc., or scrolls through the 
menu)

M

: menu key / relax mode key

OK

: confirm key, switches to the next setting and 

between automatic and manual modes

NOTES
•  The remote control does not store the programs, 

which are stored on the logic board; there is thus 
no need to reprogram it when it is shut off or 
replaced by a new one.

•  The remote exchanges information with the logic 

board (including room temperature sensing in 
automatic mode) every 2” and when it is activated 
by pressing the ON/OFF button.

•  In normal use, the remote’s batteries should last a 

year. This is an approximate value, since it depends 
on both the type of batteries and the intensity of 
use. Edilkamin and the reseller will not consider 
claims for battery life under any circumstances. If 
the battery charge is low, a warning displays at the 
top left.

REMOTE CONTROL POWER SAVING

If the remote is not used for 20”, the display turns off to 
save power. The display turns black without text.  This 
condition refers solely to the remote itself, and not to 
the fireplace.
To turn the display back on, press the ON/OFF button.

DO NOT PRESS THE ON/OFF BUTTON 
REPEATEDLY; this turns the fireplace on 
and off in manual mode

If this is the first power on and the language has not 
yet been set, the language selection page will display. 
Select the language with the +/- keys and confirm 
it with OK.You are now asked to confirm or set the 
time and date.Set the values with the +/- keys and 
confirm with OK. The day of the week is calculated 
automatically using a perpetual calendar.

REMOTE CONTROL FIRST POWER ON

  

•  Open the back of the remote and insert the 

two batteries in the indicated orientation.

•  hooked up electrically

•  THE AUDIBLE SIGNALS PRESS THE 

ON / OFF BUTTON

Otherwise it will not work

SENDING SIGNAL FROM THE 
REMOTE CONTROL TO THE 
PRODUCT IS CONFIRMED BY 
BEEP. 
IN ABSENCE OF ANY BEEP, THE 
PRESSURE ON THE BUTTON WAS 
TOO SHORT.

Содержание 807970

Страница 1: ...PELLKAMIN 12 PELLET FIREPLACE UK Installation use and maintenance 807970 807980...

Страница 2: ...ce declaration DoP EK No 137 Rating plate reference Moreover the company hereby declares that PELLKAMIN 12 complies with the requirements in the following European Directives 2014 35 EC Low Voltage Di...

Страница 3: ...ted up for the first time commissioned by a qualified Edilkamin technician In Italy commissioning by an authorised technician is required by UNI 10683 and is recommended in all countries to ensure bes...

Страница 4: ...THAN WOOD PELLETS IN THE HEARTH The product may be soiled the flue may catch fire and environmental damage may ensue cleaning the hearth when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT...

Страница 5: ...loading trapdoor PELLKAMIN 12 with ducted ventilation and a pellet loading drawer 93 60 5 2 5 5 8 cm smoke outlet 87 5 12 75 93 60 5 2 5 THE REAR THAT IS THE SAME FOR ALL 2 MODELS 10 cm ducted air 87...

Страница 6: ...for the vents V NOT SUPPLIED WITH THE PRODUCT BUT ARE ESSENTIAL E hole for ventilation air recovery a 10x10 cm hole in the side of the cladding MEASUREMENTS cm OF HOLES ON PLASTERBOARD Vents V 19 x 18...

Страница 7: ...iameter male 50 mm Weight including packaging cod 807970 220 kg cod 807980 270 kg kg TECHNICAL DATA FOR RATING THE FLUE which must in any case satisfy the requirements of this sheet and the installati...

Страница 8: ...atory fashion CONTENTS OF PACKAGE The packaging varies according to the Pellkamin version The packages are described in the Packaging section The air outlet vents are not included but you can choose t...

Страница 9: ...facilitate handling the Pellkamin 12 is fitted with handles B Do not use the air intake or fumes outlet to handle the appliance This may lead to slight misalignments TO UNPACK THE PRODUCT undo screws...

Страница 10: ...t loading trapdoor the Pellkamin frame the trapdoor loading system the two compensation vents the inlet surround Version cod 807980 with pellet loading drawer the Pellkamin frame the two compensation...

Страница 11: ...ent with regulatory grounding system Hole for ventilation air a hole at least 10x10 cm in size preferably on the side of the covering Ducting for ventilation air always channel the ventilation warm ai...

Страница 12: ...to European regulations EN 13384 EN 1443 EN 1856 and EN 1457 The installer must observe both these and any other local regulations This manual does not in any way substitute such regulations The produ...

Страница 13: ...for ensuring these conditions THE FLUE Further to the general prescriptions for the fumes duct and flue the flue must serve solely to exhaust fumes must be correctly sized to satisfy the requirements...

Страница 14: ...ION 1 2 3 4 5 6 7 8 9 10 11 12 connection V3 connection V2 Pre wired electrical power connection TERMINAL BOARDS The right side of the appliance seen from the front has a bracket with two terminal boa...

Страница 15: ...y that the plug is accessible once the installation is complete Secure the bottom of the base to the floor with 8 mm steel anchor bolts to prevent it from tipping over Position the top of the base 2 n...

Страница 16: ...Secure the loading inlet A Screw A with B Open the loading inlet to reach the screws Insulate the loading tube and make sure that it does not touch the fumes duct The loading tube must be well extende...

Страница 17: ...the technician does not adjust the parameters The air vents are not included in the product but you can choose at the retailer s which of the five available models described above best suits your tast...

Страница 18: ...LOADING DRAWER posizionarli all interno del serbatoio pellet place them inside the pellet tank Regolare i part A B C e fissarli con viti part D adjust the parts A B C and fix them with screws part D K...

Страница 19: ...2 screw the ceramic front panel to the frame with its support 3 There are 5 screws in all two on each side and one in the centre 3 replace the metal cover with the drawer Kit 2 and screw it on the si...

Страница 20: ...20 ENGLISH PELLET LOADING DRAWER 2 3 Figure 12 Drawer fitted Connecting the pipes for ducting hot air Connecting the pipes for ducting hot air 2 3 repeat on the other side 4 screws Figure 11...

Страница 21: ...an additional opening of at least 10x10 cm in size is available in one side of the cover for ventilation air recovery any wooden beams are insulated and not resting against the metal structure WE RECO...

Страница 22: ...round on to its supports secure it with the four grub screws included for the side versions fasten it to the bracket with a nut D For versions 2 with frontal ventilation and pellet loading trapdoor se...

Страница 23: ...For reasons of safety and environmental compatibility DO NOT burn plastic painted wood coal bark or other such materials in the stove Do not use the product as an incinerator Caution Using fuels other...

Страница 24: ...s ON Flame ignites and grows stable This is the result of manual ignition with ignition button request from Crono power request during stand by request from external contact Ignition has a variable du...

Страница 25: ...the type of batteries and the intensity of use Edilkamin and the reseller will not consider claims for battery life under any circumstances If the battery charge is low a warning displays at the top l...

Страница 26: ...splay shows figure 4 1 the current time 2 the current room temperature 3 the room temperature setting or manual mode 4 the power level represented by the flames 5 the fan level represented by the fill...

Страница 27: ...3 and displayed as positions 2 and 3 see below The two fans can be adjusted separately First adjust fan 2 and then fan 3 as described below Ventilation setting Press OK once The fan setting displays...

Страница 28: ...temperature setpoint is reached To access the function from the main menu as indicated in the Menu section above press the M button Scroll using the buttons and select the function by pressing OK Use...

Страница 29: ...ress the M button LOAD PELLETS STAND BY CRONO NIGHT DATE TIME DISPLAY LANGUAGE BEEP INFO TECHNICAL MENU scroll buttons OK button to confirm The following screen will appear Scroll to ENABLE underlined...

Страница 30: ...buttons Press the OK button to confirm and select SET Press the M button to go back to the previous screen press the OK button to enter the SET function ENABLE TEMP CHANGE SET scroll buttons OK button...

Страница 31: ...ckly Press the OK button to confirm and go to the temperature selection T1 T2 or T3 Press the buttons to switch between the temperatures To continue with other changes press the OK button To choose be...

Страница 32: ...n during commissioning Available only in the OFF state If you attempt to activate the function in other states access is not granted To access the function from the main menu as indicated in the Menu...

Страница 33: ...Confirm by pressing the OK button for 2 seconds Beep Allows you to enable disable the beep To access the function from the main menu as indicated in the Menu section above press the M button Scroll u...

Страница 34: ...N B Any unauthorised modification is forbidden Use spare parts recommended by the manufacturer The use of counterfeit parts results in the guarantee becoming null and void MAINTENANCE Never vacuum ho...

Страница 35: ...tray 3 and grate into a non flammable container the ashes may still contain embers and or hot parts Vacuum out the interior of the hearth the bed and the compartment around the grate into which the as...

Страница 36: ...iability for damage resulting therefrom DISPOSAL At the end of its service life dispose of the product as required by regulations Deliver to the special recycling centres The remote control s exhauste...

Страница 37: ...uantity of combustion air Check that the firebox door is closed Check that the grate and fume discharge are clean Check that the external air inlet is free i e the grilles are not obstructed Contact a...

Страница 38: ...cian MESSAGE PROBLEM SOLUTION H07 Shutdown due to exceeding maximum fumes temperature Check the type of pellet contact the technician if in doubt Contact the technician H08 Shutdown due to overheating...

Страница 39: ......

Страница 40: ...cod 941928 GB 04 18 A 941928 GB w w w e d i l k a m i n c o m...