background image

PELLKAMIN 12

PELLET FIREPLACE

UK  Installation, use and maintenance

807970

807980

Содержание 807970

Страница 1: ...PELLKAMIN 12 PELLET FIREPLACE UK Installation use and maintenance 807970 807980...

Страница 2: ...ce declaration DoP EK No 137 Rating plate reference Moreover the company hereby declares that PELLKAMIN 12 complies with the requirements in the following European Directives 2014 35 EC Low Voltage Di...

Страница 3: ...ted up for the first time commissioned by a qualified Edilkamin technician In Italy commissioning by an authorised technician is required by UNI 10683 and is recommended in all countries to ensure bes...

Страница 4: ...THAN WOOD PELLETS IN THE HEARTH The product may be soiled the flue may catch fire and environmental damage may ensue cleaning the hearth when hot DO NOT CLEAN THE HEARTH WITH A VACUUM CLEANER WHILE IT...

Страница 5: ...loading trapdoor PELLKAMIN 12 with ducted ventilation and a pellet loading drawer 93 60 5 2 5 5 8 cm smoke outlet 87 5 12 75 93 60 5 2 5 THE REAR THAT IS THE SAME FOR ALL 2 MODELS 10 cm ducted air 87...

Страница 6: ...for the vents V NOT SUPPLIED WITH THE PRODUCT BUT ARE ESSENTIAL E hole for ventilation air recovery a 10x10 cm hole in the side of the cladding MEASUREMENTS cm OF HOLES ON PLASTERBOARD Vents V 19 x 18...

Страница 7: ...iameter male 50 mm Weight including packaging cod 807970 220 kg cod 807980 270 kg kg TECHNICAL DATA FOR RATING THE FLUE which must in any case satisfy the requirements of this sheet and the installati...

Страница 8: ...atory fashion CONTENTS OF PACKAGE The packaging varies according to the Pellkamin version The packages are described in the Packaging section The air outlet vents are not included but you can choose t...

Страница 9: ...facilitate handling the Pellkamin 12 is fitted with handles B Do not use the air intake or fumes outlet to handle the appliance This may lead to slight misalignments TO UNPACK THE PRODUCT undo screws...

Страница 10: ...t loading trapdoor the Pellkamin frame the trapdoor loading system the two compensation vents the inlet surround Version cod 807980 with pellet loading drawer the Pellkamin frame the two compensation...

Страница 11: ...ent with regulatory grounding system Hole for ventilation air a hole at least 10x10 cm in size preferably on the side of the covering Ducting for ventilation air always channel the ventilation warm ai...

Страница 12: ...to European regulations EN 13384 EN 1443 EN 1856 and EN 1457 The installer must observe both these and any other local regulations This manual does not in any way substitute such regulations The produ...

Страница 13: ...for ensuring these conditions THE FLUE Further to the general prescriptions for the fumes duct and flue the flue must serve solely to exhaust fumes must be correctly sized to satisfy the requirements...

Страница 14: ...ION 1 2 3 4 5 6 7 8 9 10 11 12 connection V3 connection V2 Pre wired electrical power connection TERMINAL BOARDS The right side of the appliance seen from the front has a bracket with two terminal boa...

Страница 15: ...y that the plug is accessible once the installation is complete Secure the bottom of the base to the floor with 8 mm steel anchor bolts to prevent it from tipping over Position the top of the base 2 n...

Страница 16: ...Secure the loading inlet A Screw A with B Open the loading inlet to reach the screws Insulate the loading tube and make sure that it does not touch the fumes duct The loading tube must be well extende...

Страница 17: ...the technician does not adjust the parameters The air vents are not included in the product but you can choose at the retailer s which of the five available models described above best suits your tast...

Страница 18: ...LOADING DRAWER posizionarli all interno del serbatoio pellet place them inside the pellet tank Regolare i part A B C e fissarli con viti part D adjust the parts A B C and fix them with screws part D K...

Страница 19: ...2 screw the ceramic front panel to the frame with its support 3 There are 5 screws in all two on each side and one in the centre 3 replace the metal cover with the drawer Kit 2 and screw it on the si...

Страница 20: ...20 ENGLISH PELLET LOADING DRAWER 2 3 Figure 12 Drawer fitted Connecting the pipes for ducting hot air Connecting the pipes for ducting hot air 2 3 repeat on the other side 4 screws Figure 11...

Страница 21: ...an additional opening of at least 10x10 cm in size is available in one side of the cover for ventilation air recovery any wooden beams are insulated and not resting against the metal structure WE RECO...

Страница 22: ...round on to its supports secure it with the four grub screws included for the side versions fasten it to the bracket with a nut D For versions 2 with frontal ventilation and pellet loading trapdoor se...

Страница 23: ...For reasons of safety and environmental compatibility DO NOT burn plastic painted wood coal bark or other such materials in the stove Do not use the product as an incinerator Caution Using fuels other...

Страница 24: ...s ON Flame ignites and grows stable This is the result of manual ignition with ignition button request from Crono power request during stand by request from external contact Ignition has a variable du...

Страница 25: ...the type of batteries and the intensity of use Edilkamin and the reseller will not consider claims for battery life under any circumstances If the battery charge is low a warning displays at the top l...

Страница 26: ...splay shows figure 4 1 the current time 2 the current room temperature 3 the room temperature setting or manual mode 4 the power level represented by the flames 5 the fan level represented by the fill...

Страница 27: ...3 and displayed as positions 2 and 3 see below The two fans can be adjusted separately First adjust fan 2 and then fan 3 as described below Ventilation setting Press OK once The fan setting displays...

Страница 28: ...temperature setpoint is reached To access the function from the main menu as indicated in the Menu section above press the M button Scroll using the buttons and select the function by pressing OK Use...

Страница 29: ...ress the M button LOAD PELLETS STAND BY CRONO NIGHT DATE TIME DISPLAY LANGUAGE BEEP INFO TECHNICAL MENU scroll buttons OK button to confirm The following screen will appear Scroll to ENABLE underlined...

Страница 30: ...buttons Press the OK button to confirm and select SET Press the M button to go back to the previous screen press the OK button to enter the SET function ENABLE TEMP CHANGE SET scroll buttons OK button...

Страница 31: ...ckly Press the OK button to confirm and go to the temperature selection T1 T2 or T3 Press the buttons to switch between the temperatures To continue with other changes press the OK button To choose be...

Страница 32: ...n during commissioning Available only in the OFF state If you attempt to activate the function in other states access is not granted To access the function from the main menu as indicated in the Menu...

Страница 33: ...Confirm by pressing the OK button for 2 seconds Beep Allows you to enable disable the beep To access the function from the main menu as indicated in the Menu section above press the M button Scroll u...

Страница 34: ...N B Any unauthorised modification is forbidden Use spare parts recommended by the manufacturer The use of counterfeit parts results in the guarantee becoming null and void MAINTENANCE Never vacuum ho...

Страница 35: ...tray 3 and grate into a non flammable container the ashes may still contain embers and or hot parts Vacuum out the interior of the hearth the bed and the compartment around the grate into which the as...

Страница 36: ...iability for damage resulting therefrom DISPOSAL At the end of its service life dispose of the product as required by regulations Deliver to the special recycling centres The remote control s exhauste...

Страница 37: ...uantity of combustion air Check that the firebox door is closed Check that the grate and fume discharge are clean Check that the external air inlet is free i e the grilles are not obstructed Contact a...

Страница 38: ...cian MESSAGE PROBLEM SOLUTION H07 Shutdown due to exceeding maximum fumes temperature Check the type of pellet contact the technician if in doubt Contact the technician H08 Shutdown due to overheating...

Страница 39: ......

Страница 40: ...cod 941928 GB 04 18 A 941928 GB w w w e d i l k a m i n c o m...

Отзывы: